Compact Scaler Switcher (with PoC)
Command
Function
Feedback Example
EDID: bypass
EDID: user
50782%
EDID management, copy the best
resolution data of one output to HDMI
input
EDID manage
Resolution:1920x1080
50787%
Enable serial control mode 1: control
Scaler & far-end from local RS232
RS232 Mode 1: RS232 Control
Scaler & Remote
50788%
Enable serial control mode 2: control
Scaler from local RS232 and far-end)
RS232 Mode 2: RS232 &
Remote Control Scaler
50697%
Exit standby mode
Wake up!
50797%
Enter standby mode
Go to standby!
50698%
Software update
50617%
Reset to factory defaults
Factory Reset
Menu Commands
50609%
OK for OSD selection
Key: ok
50610%
LEFT button
Key: left
50611%
RIGHT button
Key: right
50612%
UP button
Key: up
50613%
DOWN button
Key: down
50616%
MENU button (enter OSD)
OSD: Enter
50618%
EXIT button (exit OSD)
OSD: Exit
Inquire Commands
50630%
Check the volume level
LINE Volume: xx (xx=00~66)
MIC Volume: xx (xx=00~66)
50631%
Check the input source
Input: xx (xx=
HDMI1/ HDMI2/
HDMI3/ VGA1/ VGA2/ YPbPr1/
YPbPr2/ AV1/ AV2)
50632%
Check the output resolution
Resolution: xx (xx=1920
×
1200/
1920
×
1080/ 1600
×
1200/ 1360
25