Delta Elec. Inc.
Vivitek
rev.00
Company Confidential VIVITEK_______________________ Delta____________
26
2008/07/28
3-3. LED State Indications
Power LED
Projector Status
LED Condition
LED Sequence
Projector Condition
AC Off
OFF
OFF
OFF
Cooling
ORANGE BLINK
0.5sON > 0.5sOFF
After Power OFF
Power up sequence
GREEN BLINK
0.5sON > 0.5sOFF
Start up
Standby / Idle
ORANGE ON
ON
Standby
Power ON
GREEN ON
ON
ON
WARNING LED
Projector Status
LED Condition
LED Sequence
Projector Condition
Normal Condition
OFF
OFF
Power ON
Cover ERROR
RED 1 time BLINK (repeatedly)
0.5sON > 2.5sOFF
ERROR
Temperature ERROR
RED 2 times BLINK (repeatedly)
(0.5sON > 0.5sOFF) * 2 > 2.0sOFF ERROR
Power ERROR
RED 3 times BLINK
(0.5sON > 0.5sOFF) * 3 > 2.0sOFF ERROR
FAN ERROR
RED 4 times BLINK (repeatedly)
(0.5sON > 0.5sOFF) * 4 > 2.0sOFF ERROR
Keylocked (when push key)
ORANGE light up
ON
Keylock function enable
Standby (Power-saving)
OFF OFF Standby
(Power-saving)
Standby (Normal)
GREEN LIGNT
ON
Standby (Normal)
Lamp LED
Projector Status
LED Condition
LED Sequence
Projector Condition
Lamp Off
OFF
OFF
Lamp Off
End of the Lamp life
RED BLINK
0.5sON > 0.5sOFF
Replace Lamp
NO LAMP
RED 1 time BLINK (repeatedly)
0.5sON > 2.5sOFF
ERROR
Lamp ERROR
RED 6 times BLINK (repeatedly)
(0.5sON > 0.5sOFF) * 6 > 2.0sOFF ERROR
Cooling Lamp
ORANGE BLINK
0.5sON > 0.5sOFF
Switching Lamp 1 & 2
Re-Light up sequence
GREEN BLINK
0.5sON > 0.5sOFF
Start up
Lamp life Over
RED ON
ON
Replace Lamp
Eco mode
ORANGE ON
ON
Power ON
Normal mode
GREEN ON
ON