ENG
VIVAX
17
Fast DHW
The FAST DHW function is used to force the
system to operate in DHW mode.
The heat pump and the booster heater or
addition heater will operate for DHW mode
together.
Go to
MENU> DOMESTIC HOT WATER >FAST
DHW
.
Press "
OK
"
Use "
ON/OFF
" key to select ON or "
OFF
".
INFORMATION
If CURRENT STATE is OFF, the FAST DHW is
invalid, and if CURRENT STATE is ON, the
FAST DHW function is effective.
The FAST DHW function is once effective.
TANK Heater
The tank heater function is used to force the
tank heater to heat the water in tank. In the
same situation, the cooling or heating is
required and the heat pump system is
operating for cooling or heating, however
there still is a demand for the hot water.
TANK HEATER function can be used to heat
the water in tank.
Also, even if the heat pump system fails,
TANK HEATER can be used to heat water in
tank.
Go to
''MENU'' > ''DOMESTIC HOT WATER''
> ''TANK HEATER''.
Press
OK.
Use ''
ON/OFF
'' to select
ON
or
OFF
.
Use ''
BACK
'' to exit.
If TANK HEATER is effect, the following page
will appear.
INFORMATION
If CURRENT STATE is OFF, TANK HEATER is
invalid.
If the T5 (sensor of tank) is fault , tank
heater can’t work.
Summary of Contents for HPS-120HM155AERI/I3
Page 2: ......
Page 53: ...VIVAX HR 50 DODATAK B Dijagram ožičenja s električnim upravljanjem 4 10kW ...
Page 57: ...VIVAX HR ...
Page 58: ... HR VIVAX 1 ...
Page 85: ...VIVAX HR 28 STRUKTURA IZBORNIKA PREGLED ...
Page 86: ... HR VIVAX 29 ...
Page 90: ...VIVAX ...
Page 141: ...VIVAX ENG 50 ANNEX B Electrically controlled wiring diagram 4 10kW ...
Page 145: ...VIVAX ENG ...
Page 146: ... ENG VIVAX 1 ...
Page 173: ...VIVAX ENG 28 MENU STRUCTURE OVERVIEW ...
Page 174: ... ENG VIVAX 29 ...
Page 178: ......
Page 196: ...3 4 3 4 3 4 ...
Page 199: ......
Page 200: ...ZZZ 9 9 FRP ...