3. IPM continuity check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
Normal resistance value
Digital tester
Normal resistance value
(+)Red (-)Black
∞
(Several M
Ω
)
(+)Red (-)Black
∞
(Several M
Ω
)
P
N
U
N
U
V
V
W
W
(+)Red
4: Indoor AC Fan Motor
Measure the resistance value of each winding by using the tester.
Posi
tion
Resistance Value
RPG20D(
Weilng)
RPG28D(T
ongDe)
RPG28D(
Dayang)
RPG20E(T
ongDe)
RPG20E(
Weilng)
RPG13H(
Weilng)
RPG25(T
ongDe)
YSK68-4P(
Weilng)
YDK37
-4P
Blac
k -
Red
398
Ω
±8%
(20
℃
)
255
Ω
±8%
(20
℃
)
271.3
Ω
±8
% (20
℃
)
415
Ω
±8%
(20
℃
)
387
Ω
±8%
(20
℃
)
575
Ω
±8%
(20
℃
)
295
Ω
±8%
(20
℃
)
285.8
Ω
±8
% (20
℃
)
258.7
Ω
±8%
(20
℃
)
Red -
Yello
w
345
Ω
±8%
(20
℃
)
335
Ω
±8%
(20
℃
)
347.8
Ω
±8
% (20
℃
)
396
Ω
±8%
(20
℃
)
378
Ω
±8%
(20
℃
)
558
Ω
±8%
(20
℃
)
420
Ω
±8%
(20
℃
)
178.5
Ω
±8
% (20
℃
)
189.7
Ω
±8%
(20
℃
)
Yello
w -
Blue
345
Ω
±8%
(20
℃
)
335
Ω
±8%
(20
℃
)
347.8
Ω
±8
% (20
℃
)
396
Ω
±8%
(20
℃
)
378
Ω
±8%
(20
℃
)
558
Ω
±8%
(20
℃
)
420
Ω
±8%
(20
℃
)
178.5
Ω
±8
% (20
℃
)
189.7
Ω
±8%
(20
℃
)
Summary of Contents for ACP-18COFM50AECI
Page 2: ......
Page 10: ...4 Wiring Diagram ACP 18COFM50AECI ...
Page 11: ...ACP 27COFM79AECI ACP 28COFM82AECI ...
Page 12: ...ACP 41COFM123AECI ACP 36COFM105AECI ...
Page 41: ...10 3 1 2 Indoor outdoor units communication error ...
Page 48: ...10 3 2 2 Communication malfunction between IPM board and outdoor main board ODU E3 ...
Page 63: ......
Page 64: ...www VIVAX com ...