MALFUNCITON AND MAINTENANCE
Malfuction
Possible reasons
Solution
No action
1.Power off or poor connection
2.Not press the power at the back of
body.
3.Not Press the "ON/OFF" key on
the control panel.
1.Plug the power cord and
make sure it connects well.
2.Press the power at the back
of body.
3.Press the "ON/OFF" key on
the control panel.
Poor result of
dedusting
1. Block the air filter screen with
dust.
2. Block the air inlet with corpus
alien.
1.Remove and clean the air
filter screen.
2.Remove corpus alien from
the air inlet.
Repair the appliance under the situation as follows:
1. Abnormal action or no action.
2. Abnormal action since ingress of water or corpus alien.
STORAGE INSTRUCTIONS
The fan should be stored in a cool, dry place.
Do not alow to be in reach of children.
DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT
To protect our environment and to recycle the raw materials used as
completely as possible, the consumer is asked to return unserviceable
equipment to the public collection system for electrical and electronic.
The symbol of the crossed indicates that this product must be returned to the
collection point for electronic waste to feed it by recycling the best possible
raw material recycling.
By ensuring this product, you will prevent possible negative effects on the environment and
human health, which could otherwise be caused due to improper disposal of that product.
The recycling of materials from this product, you will help to preserve a healthy
environment and natural resources.
For detailed information about the collection of EE products contact the dealer where you
purchased the product.
EU DECLARATON OF CONFORMITY
This device is manufactured in accordance with the applicable European
standards and in accordance with all applicable Directives and
Regulations.
EU declaration of conformity can be downloaded from the following
link:
www.msan.hr/dokumentacijaartikala