5 Operation
5.8 Sonde Mode
A Sonde is typically used for locating non metallic pipes or ducts. The Sonde operating
frequencies for the 800 series are:
•
VM-810 operating frequency is 83.0775 kHz
•
VM-850 operating frequency is 9.82 kHz
5.8.1
Checkout Procedure for Locating Sondes
To ensure proper operation of the Model VM-810/850 Sonde and Utility Line Locator,
use the checkout procedure below at the following times:
•
upon receiving the equipment
•
before each job, preferably before you leave for the site
•
if problems arise during a locate
1. Switch on the receiver. Double click the on/off button to activate Sonde mode.
Check battery status.
2. Switch on Sonde and place on ground away from metal objects such as rebar.
3. Position Receiver within one foot or so of the Sonde and check high signal
strength reading on Receiver. Receiver displays higher signal strength when over
the Sonde.
5.8.2
Operation in Sonde Mode
1. Energize the Sonde - ensure batteries are in good condition and place in Sonde.
Switch Sonde “ON”.
2. Check Sonde is transmitting - Position Receiver within one foot or so of the
Sonde and check high signal strength reading on Receiver. Note Receiver
displays higher signal strength with over Sonde.
Page 23 of 35
™