VIMATY 70

5.2.1 - IR learning with the integrated infra-red receiver.

  

Vimaty can directly learn the infra-red codes from your remote controls. Use preferably  the 

mode     of  "Normal"   learning   which   is   a   mode   which   controls   the   measurements   taken   before 
validating them. This mode is thus more protected than the "Forced" mode that accepts all taken 
measurements.

Check the absence of parasitic infra-red sources (fluorescent lights, television, LCD screen) 

Pass in learning mode by using the setup mode. The following screen appears :

Choose the learning mode with the button "Learn" 

Choose the type of learning with the button "Normal". 

Choose the infra-red code to learn by pressing  the button on the touch screen. 

The message "IR learning in progress" appears at the bottom of the screen. The touch screen 
is not read any more and if you want to leave the learning mode, press one pushbuttons of 
Vimaty. The exit of this mode is automatic if the learning is not successful at the end of 15 
seconds. 

Send the infra-red code of your remote control in direction of Vimaty's infrared receiver on the 
center of the bottom of the Vimaty70(the remote must be between 20 and 50 cm far away of 
the infrared receiver to allows good infrared learning).

The   buzzer   is  activated  when   the  code  was   learned  and  the   message   "IR  Code  Learned" 
appears in the bottom of the screen. 

In the learning mode, the touch screen is inactive. To force the exit of the learning mode, it is 
necessary to press one of the buttons. 

If the learning did not function with your remote control, choose the mode "Forced" and starts 
again the operation. (the forced mode seizes the infra-red data without controls) 

5.2.2 - Upadte IR code with CompactFlash

  

The PC2Maty software associated with the infra-red data base in Ir dump can avoid you the 

tiresome work of infra-red learning . It is enough for you to declare the type of devices and the 
function   necessary   for   the   infra-red   codes   and   PC2Maty   generates   automatically   during   the 
compilation of your project, an infra-red data file for your application in the CompactFlash. 

To update infra-red data on Vimaty, it is necessary to click on the button called “Load IR 

codes”, or touch simultaneously the screen and the push button on the center of the left side of 
the screen.

15/33

Summary of Contents for VIMATY 70EIB

Page 1: ...A T Y 7 0 S V I M A T Y 7 0 E I B V I M A T Y 7 0 S W A L L V I M A T Y 7 0 E I B W A L L V I M A T Y 7 0 G L S V I M A T Y 7 0 E I B G L S D e s k t o p s e r i e s U ser M an u al W a l l s e r i e...

Page 2: ...his manual may be copied or reproduced in any form without prior written consent of VITY Technology Headquarters France VITY Technology is not responsible for operational technical or editorial errors...

Page 3: ...ce detector 12 4 10 Date and time 12 4 11 MBC Bus RS485 Interface 12 4 12 Infrared interface 12 4 13 RS232 Interface 12 4 14 EIB interface 13 4 15 Calendar action by day of the week and hours 13 5 PRO...

Page 4: ...F reader of the VIMATY 70GLS 27 6 4 Cabling of a VIMATY 70S 28 6 5 Cabling of a VIMATY 70EIB 29 6 6 Direct cabling with RJ 45 Vity cable non Ethernet 30 6 7 Cabling infrared connecting block 31 7 BRAN...

Page 5: ...and hours By perpetual calendar Communication with connection interface 1 x RJ 45 Colors Available in 2 versions White or Black silver Video inputs 4 CVBS or 2YC or 1YC 2 CVBS Temperature From 0 C to...

Page 6: ...of interconnection PC2MATY software PC2MATY licence 1 3 2 Wall version We have 4 different models for wall version Vimaty 70S WALL infrared output RS 232 in out MBC Bus in out GPI or IR in Vimaty 70E...

Page 7: ...VIMATY 70 1 3 3 Front of the VIMATY 70 7 33...

Page 8: ...VIMATY 70 1 3 4 Back of the VIMATY 70 8 33...

Page 9: ...trix switcher scaler The Vimaty can send commands and receive a feedback RS 232 feedback 2 3 MBC Bus RS485 Vity applications All Vimaty 70 have an RS 485 MBC Bus port to command Vity controllers Monop...

Page 10: ...stored in a CompactFlash So it is easy to recover the source program to update the application With the application on the CompactFlash it is easier to change the applications by simply changing the...

Page 11: ...Touch screen The touch screen makes it possible to browse between the various screens of the application Each screen displays control buttons that allow to send commands to the devices connected to th...

Page 12: ...ersion 4 8 Backlight The screen backlight is adjustable according to the ambient luminosity see setup 4 9 Presence detector The screen backlight is disabled at the end of an adjustable time When a pre...

Page 13: ...he communication on the standard EIB KNX bus Can accept 240 addresses of 8 Bit each Example KNX device like Switchers take 1 Bit Curtain command take 2 Bits one UP one DOWN Dimmer take 8 Bits Temperat...

Page 14: ...ARNING allows the learning of the infra red codes used by your application The button DATE HOURS allows the setting the Vimaty time Button SCREEN allows the adjustment the backlighting screen the scre...

Page 15: ...irection of Vimaty s infrared receiver on the center of the bottom of the Vimaty70 the remote must be between 20 and 50 cm far away of the infrared receiver to allows good infrared learning The buzzer...

Page 16: ...the modification is immediately effective When you set up time the Vimaty all Vimaty connected to bus RS485 are set up 5 4 Screen button On this page you can update several parameters These values ar...

Page 17: ...lean the screen appears After cleaning you can unlock the touch faceplate by pressing one of the five other push buttons For the GLS version you have to press the screen during 4 seconds 5 4 2 Calibra...

Page 18: ...r functions are accessible by this screen 5 6 1 Load parameters from CompactFlash card These values are defined in the file vimaty ini are the backlight level The sleep time the state buzzer the Vimat...

Page 19: ...n of OS is higher than that already installed on Vimaty The update can be forced if the button at right hand side is pressed when a CompactFlash is inserted Some OS update integrate BIOS updates For t...

Page 20: ...tor Connecting block 2 points 0 14mm with 0 5mm Gauge 28 20 Connection for a standard dry contact input which acts on the operation of your application The connection for an infra red input which acts...

Page 21: ...certain points are connected to the common mass of the device Points located 0 on connectors Bus 485 MBC Bus Point located 0 on connectors Bus 232 Point located on the connector In LOG Point located...

Page 22: ...l version 6 2 1 Wiring of the connecting card The case of embedding has a interconnection card inside The wiring has the same definition that the interface connection see below VIMATY 70S WALL VIMATY...

Page 23: ...e wall according to the drawing 2 Insert the case to be embedded 3 Use the grip of fixing to block the case 4 Connect the electric cables 5 Fix the Vimaty 70Wall using the 4 provided M4 screws 6 Snap...

Page 24: ...VIMATY 70 6 2 3 Wall cut out of Vimaty 70WALL version 24 33...

Page 25: ...VIMATY 70 6 3 GLS version 6 3 1 Wiring of the connecting card 25 33 VIMATY 70S GLS VIMATY 70EIB GLS...

Page 26: ...VIMATY 70 6 3 2 Wall cut out of Vimaty 70GLS 26 33 Depth 52 mm 2 05...

Page 27: ...VIMATY 70 6 3 3 How to access to the CF reader of the VIMATY 70GLS 27 33...

Page 28: ...VIMATY 70 6 4 Cabling of a VIMATY 70S It is the same cabling system for Vimaty 70S WALL and GLS with the integrated interconnection interface 28 33...

Page 29: ...VIMATY 70 6 5 Cabling of a VIMATY 70EIB It is the same cabling system for Vimaty 70EIB WALL and GLS with the integrated interconnection interface 29 33...

Page 30: ...t If you use VIMATY 70S you don t need to use interconnection interface You can directly connect the devices with the RJ 45Vity cable delivered with the Vimaty Fot the Vimaty 70EIB you have to use the...

Page 31: ...in order to drive devices by infrared it is recommended to use infrared connecting block with infrared emitters We propose in option these products VRPT 104 1 infrared connecting blocks with 4 infrare...

Page 32: ...us Control can control more systems 3M ABB Adtec Akg AllenHeath Analogway Ask Autopatch Barco Behringer Biamp Canon Clipsal CommTec DIS Epson Extron Faroudja Fostex Gyra Hager Imerge Jung JVC Kenwwod...

Page 33: ...en VITY disclaims and excludes all other warranties whether express implied or statutory 4 Buyer s Exclusive Remedies for Any Nonconformity If a VITY product fails to conform to the warranties in Sect...

Reviews: