1-2  Bathtub must be carried upside down. It must never be carried by holding from its panel.
3-  In this series a ‘hidden overflow’ is installed to plain and hydro massage bathtubs by the manufacturer. Therefore the product comes with the 

siphon installed.  The bathtub is placed on the installation area and the perimeter of its bottom is marked. Inside the marked area, the 50 
mm diameter waste water drain pipe is installed from the center shown in the drawing, at the point indicated by the letter “A”, and the water 
inlet pipes are installed to the centerline of the faucet above the bathtub, at the point indicated by the letter “C", as illustrated in the technical 
diagram. If this is a hydro massage (hydro massage) bathtub, a 220 V phase, neutral and earth electric lines are required to be connected 
inside the marked area, in accordance with the orientation of the bathtub (seethe area indicated by the letter “E").No water drain muff should 
be left in the area indicated by the letter “B”. External faucet application should be carried with a minimum distance of 100mm to the bathtub 
and in accordance with the bathtub placement. The axle distance between the hot and cold water inlet pipes should be adjusted in 
accordance with the technical drawing of the faucet. (See the Technical Data Sheet for the technical scheme).

7-  The parts of the bathtub’s monobloc sides that touch the floor should be marked. The panel supporting brackets should be pulled inside at 

the thickness of the acrylic and they should be fixed to the floor with silicone. Accordingly, movement of the bathtub on the floor is 
prevented.

8-  The siphon drain pipe connection and also the electrical connection (if the product is hydromassage) of the bathtub should be made.
9-  Tighten the leg set nuts.

10-  Apply silicone on the bathtub legs’ parts which contact the floor.
11-  When the infrastructure installation is completed the taken down from the bearing supports. When deemed necessary apply silicone to 

several points between the bathtub panel and the floor and complete the installation

12-  The installation of the monobloc bathtub is completed. Any remaining protective folio on the bathtub should be removed only after the 

bathtub installation and any other construction works in the bathroom are finished.

4-5  The bathtub is taken into level using a scale at the installation area.
6-  For the infrastructure installation, the bathtub is placed on bearing supports at the installation area.

Caution: 

During the infrastructure installation, the bathtub should not be tilted sideways and no weight should be placed on its side panels.

Installation of Monobloc Bathtubs

Summary of Contents for Neon

Page 1: ...ft Aqua Maxi Air Relax Aqua Soft Aqua Soft Easy 3 Front View Ön Görünüş 2 Side View Yan Görünüş As shown in Figure Plan the wall hangers details A B are used to fix the product to the wall It is suggested to use the wall hangers to rigid the shower tray Plan görüntüde şekil 1 A ve B olarak gösterilen duvar askı elemanları ürünü duvara sabitlemek amacıyla kullanılır Duş teknesinin rijitliğini sağla...

Page 2: ...n için ek pay b rak lmas na gerek yoktur Ürünün ebad dikkate al narak gereken alan n haz rlanmas yeterlidir The area where the waste outlet Ø 50 mm can be placed in A Ideal position of the waste outlet Ø 50 mm The end point of the waste outlet should not be cut out and should be left at least 50 mm above the surface B The area Ø 200 mm where the waste outlet should not be left C Hot cold water inl...

Page 3: ... Artema Yetkili Servisleri ne Ücretsiz olarak yaptırılması gerekmektedir Masajlı Küvetler in Ücretsiz Montaj Uygulaması kapsamına standart bir küvet montajında kullanılan VitrA silikon dirsek ve 50 mm lik uzatma hortumu da dahildir Kenar çıtası gibi ilave aksesuarlar bu uygulamaya dahil değildir Masajlı Küvetler in gömme uygulamasında kesinlikle havalandırma ve müdahale kapakçığı bırakılmalıdır Bu...

Page 4: ...duct should be protected with an appropiate ampere fuse for Aqua Nano System 16 ampere Duo Maxi and Duo Soft Systems 16 ampere for Aqua Maxi Aqua Soft Aqua Soft Easy and Air Relax System 10 ampere and the amper fuse should be closed when it is not used Küvet masajlı ise uygun Amperdeki sigorta ile koruma altına alınmalıdır Sigorta akım değeri Aqua Nano sistemi için 16 Amper Duo Soft ve Aqua Maxi s...

Page 5: ...ACRYLIC BATHTUBS Installation Applications and User s Manual ...

Page 6: ...s Not Covered Under Warranty 11 Transportation Storage 11 Installation 11 Use Cleaning and Maintenance 11 November 2015 www vitra com tr Manufacturer Company Eczacıbaşı Yapı Gereçleri San ve Tic A Ş Șekerpınarı Cumhuriyet Mah İsmet İnönü Cad No 27 41420 Çayırova Kocaeli Tel 0262 648 95 00 Pbx Faks 0262 658 85 94 Consultancy Line 0850 311 70 70 0532 755 75 00 General Distribution Central Service İn...

Page 7: ...rom our seller for the telephone number of the Authorized Service in the area you are living in In places where we do not have a seller you may get the necessary information from the telephone numbers given in the guide Ask the service personnel to display their Vitra Artema Authorized Service Personnel Card Do not let people without a personnel card perform the installation At the completion of t...

Page 8: ...not deform Any small scratches which might occur on the surface can easily be eliminated through polishing Acrylic products do not lose their shine due to a homogenous distribution of color cells and saves the first day appearance over years The acrylic plates used in the production of VitrA Acrylic Bathtubs meet the EN 263 Standards for Acrylic Plates and are supplied from Lucite International ICI...

Page 9: ... The bathtub is placed upside down on a clean floor and the U shaped legs are inserted to the toggle and fixed to the bottom of the product via two screws 3 The toggle screws are tightened 4 Remove the protective folio of the bathtub from its sides that are touching the wall and from the area around the siphon Note The remaining protective folio on the bathtub should be removed only after the bathtu...

Page 10: ...massage bathtub the electrical connection should be made 21 For rectangular bathtubs first the side panel and later the front panel are installed to the bathtub For corner bathtub panels fixed metal clips are available for panel installation under the front side rims of bathtub to fix the panel The panel s installation is started from one corner by attaching the top band of the panel to these clips 2...

Page 11: ...adjusted in accordance with the technical drawing of the faucet See the Technical Data Sheet for the technical scheme 7 The parts of the bathtub s monobloc sides that touch the floor should be marked The panel supporting brackets should be pulled inside at the thickness of the acrylic and they should be fixed to the floor with silicone Accordingly movement of the bathtub on the floor is prevented 8 Th...

Page 12: ...cal Features MASSAGE SYSTEMS IMPLEMENTED IN VİTRA BATHTUBS 8 If your VitrA bathtub without massage functionality is a model which is suitable for the implementation of a hydro massage system you can convert it into a massage bathtub and enjoy the pleasure of hydro massages You can have a suitable massage system installed to your VitrA plain bathtub you have purchased and are using anytime you want...

Page 13: ...Automatic air massage intensity setting Intermittent air massage Continuous air massage Manual water massage intensity setting Automatic water massage intensity setting Intermittent water massage Continuous water massage pneumatic ABS or chrome coating 18 0 8 220 230 10 2 halogen lamps optional 12 0 04 220 230 10 chrome coating over brass chrome coating over brass 21 0 8 220 230 10 electronic elec...

Page 14: ...earest VitrA Artema Authorized Service MATTERS THAT REQUIRE ATTENTION Acrylic is durable against acids and alkalines However do not let organic solutions used in dry cleaning paint remover substances acetone or other solvents to your compact system Keep lighted cigarettes away from the product If the construction activities in the bath will continue after installation do not remove the folio layer...

Page 15: ... Products damaged by each other due to stacking on top of each other during storage shall be treated out of scope of the warranty Installation 1 Failures which occur as the result of incorrect installation maintenance repairs and disassembly performed by unauthorized persons 2 Factors which impact the installation of the product resulting from the wall or floor not being level or hot cold water was...

Page 16: ......

Reviews: