background image

2

3

NOTES

• Please read these instructions carefully before using the product and keep this for future reference.

• All the examples and pictures used here are for reference only.

• The contents of this manual are subject to change without notice.

• This device should be operated only from the type of power source indicated on the label. Also, verify 

the voltage.

• 

PLEASE CHECK

 the device and accessories upon purchase. If there is any damage, shortages or 

defects, please contact your VITEK Reseller immediately.

HDD INSTALLATION

• This Network Video Recorder supports 1 SATA hard drive. 

•  Please make sure that the device is powered off before installation. The pictures of the installation 

are for reference only. In the event of a discrepancy, refer to the actual product.

 Loosen the screws to open the cover.

 Insert the screws into the HDD but do not tighten them.

 Place the HDD onto the bottom of the recorder.

 Turn over the machine and secure the HDD with included screws.

 Connect the power and data cables.

 Re-install the cover and secure it with the screws.

Tip: Please check the inside structure of the device and make sure the cables are well connected

before re-installing the cover.

REAR PANEL INSTRUCTION

*Product ports and rear panel features table on following page

Summary of Contents for TRANSCENDENT VT-TNR818TPH

Page 1: ... Allow Block VIP Features Facial Search by Picture by Temperature Time Camera Event and Mask with Ability to Add Pictures through App Web and External Import Allow Block VIP Temperature Exception Alarm Attendance Management by Week Month Custom Face Greeting View and Settings via Web Client Access Control Trigger by Staff VIP Allow List Alarm Modes Motion Sensor Detection A I Event Temp Exception ...

Page 2: ...ork Video Recorder supports 1 SATA hard drive Please make sure that the device is powered off before installation The pictures of the installation are for reference only In the event of a discrepancy refer to the actual product Loosen the screws to open the cover Insert the screws into the HDD but do not tighten them Place the HDD onto the bottom of the recorder Turn over the machine and secure th...

Page 3: ...e wizard when you start the NVR for the first time Choose the language and read the privacy statement Then set the data time and zone as needed After that set the login password The default username is admin and the default password is 123456 Set your own password or use the default one when you use the wizard for the first time Enable pattern lock and click Edit to set the pattern lock Then set t...

Page 4: ...ES Enter IP address subnet mask gateway If using DHCP please enable DHCP in both the NVR and the router Enter HTTP port the default value is 80 and server port default is 6036 The internal ethernet port connects all PoE ports in the NVR system The ports are available if the internal ethernet port is online if it is offline all ports will be unavailable Add Camera Click Next to go to the following ...

Page 5: ... NETWORK ADDRESS TRANSLATION NAT You can enable the NAT function in the interface or set it in the network configuration after exiting the wizard You can scan the QR code through the mobile surveillance APP for iOS or Android to easily view your cameras Web Client Access Through NAT Function Enter www autonat2 com in the address bar of your browser and then press enter to go to the following inter...

Page 6: ... is suggested Facial IPC IP Cameras which support face recognition can choose this one PEOPLE MANAGEMENT Click Start People Management to go to the people management interface 1 Click and then set the company name department and position of people 2 Add face pictures and relevant information for each group Select a group and then click Add to go to the following interface Click Select face to choo...

Page 7: ...ws Note Currently only when the face picture is added to the face database and successfully matched by the IP Panel can the Smart Management Terminal SMT show the temperature and picture of the person LIVE DISPLAY Area Real time statistical information display Area Real time intelligent detection information display including face match body temperature mask status area etc Area Real time face cap...

Page 8: ...d Business Trip Settings Go to the Leave and Business Trip interface and then click Add to pop up a window Click Add to add the person who takes leave or a trip then set the start and end time 3 Attendance Search Set the filter condition attendance date attendance area Then click Search to search the attendance information of staff Select a person click to view their detailed attendance informatio...

Page 9: ... Modify Delete and Search Face Pics by Time Camera Event Temperature Mask Add w App Web Ext Import w 128 128 Res 1920 1080 jpg 150KB Temp Exception Alarm Allow List Block List VIP Stat Info by Day Week Month Quarter and Custom Period in Bar Graph or Pie Chart 8 Ch Temp Measurement F C Face Recognition w Masks Time Sliced Image Time Calendar Event Motion Ext Alarm Tag Sensor Motion Detection A I Ev...

Page 10: ...Mount Available Optional Wall Pole Mounts Available VT TSP8 Transcendent Series 2 MP Temperature Screening Camera with 8 inch Display Panel VT TNB5TH Transcendent Series 5 MegaPixel Bi Spectrum Long Range Thermal WDR IP Motorized Bullet Camera w VT BB501 Blackbody Temperature Calibration Device sold separately ...

Page 11: ... products eliminate the need for expensive and troublesome long distance cables in areas where CCTV monitoring and rigorous surveillance take place These small lightweight and durable units are easy to install and easy to use with an innovative and straitghtforward 10 button plug and play dip switch that facilitates the creation of a robust wireless network without a computer Set up can be simply ...

Page 12: ...ed with in any way or the guarantee will be considered null and void This guarantee does not affect your statutory rights Contact your local VITEK Reseller should servicing become necessary 28492 CONSTELLATION ROAD VALENCIA CA 91355 WWW VITEKCCTV COM Version 2 0 July 2020 CLASS A DIGITAL DEVICE INDUSTRIAL COMMERCIAL ENVIRONMENT This equipment has been tested and found to comply with the limits for...