![Vitec Multimedia FIM-102D Instruction Manual Download Page 27](http://html1.mh-extra.com/html/vitec-multimedia/fim-102d/fim-102d_instruction-manual_1034960027.webp)
3-2
FIM-102D FIBER INTERFACE
SYMPTOM
POSSIBLE CAUSE
No operation, indicators all off. No power.
Make sure the external power
supplies are plugged in to a 120
VAC outlet and to the power
receptacle on the FIM-102
No operation, RX Optical Link
and RX Digital Lock leds are not
lit.
Optical communications failure.
Check for broken or
disconnected fibers. Check to see
if the FIM-102 at the other end
is operating correctly.
FIM-102 units are operating
correctly, but connected stations
or interfaces are not.
Check RJ-45 cables or Matrix
configuration.
If you are unable to resolve a problem with your FIM-102 unit, call Clear-Com Intercom Systems at (510) 496-6666
and ask for the Service Department. See the Warranty Chapter for more information.