1-6
FIM-102D FIBER INTERFACE
CONNECTING INTERFACE MODULES TO THE CENTRAL MATRIX
With a pair of FIM-102D units you can also remotely connect Clear-Com rack-mounted Matrix interface modules to
the central Matrix. For example, using a Clear-Com CCI-22 dual party-line interface at one end, you can connect two
independent, external 2-wire party line systems to the central Matrix from a distance of up to 12 miles (20 km). Or,
with a Clear-Com TEL-14 Telephone Interface Module, you can send telephone audio to the central Matrix over a
secured interference-free fiber-optic line. By using a Clear-Com FOR-22 4-wire interface module, you can send 4-
wire audio plus transmit keying over a fiber-optic line. You can also use a Clear-Com EF-1M to interface 2-wire
Clear-Com or RTS party lines to the central Matrix over a fiber-optic link.
Figure 2 shows a system with connected interface modules.
FIM-102D
FIM-102D
CCI-22 Interface
TEL-14 Interface
Connects two 2-wire
party-line circuits
Connects 2 tele-
phone lines
EFI-M Interface
Connects 2-wire
party-line to matrix
or other 4-wire devices
or
or
Figure 2: Connecting Interface Modules to the Central Matrix