Vitavia IDA 5200 Assembly Instructions Manual Download Page 4

4

assembly Instructions

 

Site Selection

  

Always try to select a sunny location, sheltered 

from the wind as much as possible. 

  

 important

 

 

Before assembling your new greenhouse, 

please check that all parts in the provided list 

are included. Please take each bundle out of 

the packaging in order to identify the parts 

better.
It is important that the opened bundles do not 

get mixed with one another.
If something is missing please contact your 

retailer.

important!

 The UV-resistant side of the 

polycarbonate panes is indicated by the plastic 

film and printing at the edge. This side must 

face outside. Remove the film. 

nuts (1002) - max. tightening torque 3nm.

 

neceSSary toolS

 

 

Screw drivers (Normal and Crosshead PH2), 

10 mm socket spanner or wrench, 10 mm 

combination spanner, knife, measuring stick, 

spirit level, Accu-drill with adjustable torque.

 

maintenance

 

 

The greenhouse should be thoroughly washed 

with a gentle detergent occasionally. Please 

check that the detergent used does not react 

aggressively with aluminium or the glass fixing 

clips. 
Ensure that the upper and lower door tracks 

are cleaned regularly to avoid a build up of 

debris. 

 0. BaSe

  

important! 

The base must be exactly square 

and level. A zinc-coated steel base is available 

as an accessory for all greenhouse models.  
(

attention!

 Only when the greenhouse has to  

be located in a very windy and unprotected 

location: Drill through both the profile at the 

base of the greenhouse and the steel base, 

and connect them with nuts and bolts.)

If you would rather construct your own stone 

or concrete foundation, please follow the  

dimensions specified in diagram 0. Treated 

wooden beams at least 18 mm high and not 

more then 32 mm wide should be positioned 

between the stone/concrete foundation and 

the aluminium frame, and connected to the 

foundation with 50 mm long bolts (not pro-

vided). 

Foundations must extend down below the frost 

level.

Diagrams in a single frame show the view 

from inside the greenhouse. those enclo-

sed in a double frame show the view from 

outside the greenhouse.

 

 1. Front

 

 

Lay all of the parts on the floor and connect 

them loosely. 
Loosely connect the corner plates (1092) on 

the upper corners (1.5).

note:

 Several door assemblies are possible.

A double door can be positioned in any 2 

fields, with the exception of the corner fields, in 

the front of the greenhouse. (See section 5B)
Two single doors can be assembled in diffe-

rent combinations on the side or front of the 

greenhouse. (see section 5A). Two single  

doors on both sides is indicated by „SDS“.
Please decide at this point how and where you 

wish the doors to be assembled and follow the 

appropriate diagram. 

note:

 The fields on both sides of a door ope

-

ning require a middle brace. (1.6 - 1.9)

 2. SiDe aSSemBly

 

 

Assemble wall bars (4248 / 4249) with sill bars 

(5546) (2.1) and horizontal bars (4261 / 4262) 

(2.2) (2.3). Loosely connect glazing bars 

(4232) between the sill bars and horizontal 

bars (1.2) (2.5).
Loosely connect both side assemblies to the 

front assembly including diagonal braces 

(4233) (2.4) (2.6) (2.7) and if required, middle 

braces (2096) and (2097). 
Loosely connect roof corner bars (4237 / 

4238) between the wall bars (4248 / 4249) and 

the eave bar (4227 / 4228 / 4229) using corner 

plates (1092) (2.8) (2.12).
Loosely connect the ridge bar (4251 / 4252 / 

4253) between the roof corner bars using 

plates (1092) (2.8) (2.9).
Loosely connect glazing bars (4241 / 4242) 

and (4243 / 4244) between horizontal bars 

(4261 / 4262) and roof corner bars (4237 / 

4238) (2.10) (2.11).

 3. rooF aSSemBly

 

 

Position the roof glazing bar(s) (4255) on the 

ridge bar (3.4) and over the eave bar (3.5).

note :

 It is necessary to include two extra 

bolts in the bolt channel in glazing bars (4255) 

at this point, to later connect the roof vent and 

strengtheners (3.4) (3.5).
Loosely connect roof strengtheners (4270)  

underneath glazing bars (4255) (3.6) (3.8). 

Insert the extra bolts in (4255) through the 

prepared holes (3.7). 

note:

 Ensure roof bars 

(4255) sit against the lip on the ridge bar.
Loosely connect the gutter bar (4264 / 4265 / 

4266) to roof glazing bars (4255) (3.9) and 

both roof corner bars (4237 / 4238) (3.10) 

(3.11).

 4. aSSemBly on Wall

 

 

Now position your greenhouse on the pre-

pared base/foundation and connect loosely. 

Adjust the greenhouse until it is completely 

square and tighten all bolts. 

please do not over tighten. (max. 3nm)

Ensure that the sides are perfectly vertical. 

1. 

pleaSe reaD tHeSe inStrUctionS careFUlly anD completely BeFore aSSemBlinG yoUr GreenHoUSe.

 

2.   Sharp edges and corners can cause injury. Always wear protective glasses, gloves, shoes and headgear when handling the aluminium profiles, glass and 

polycarbonate sheets. Broken glass is a safety hazard – always clear up immediately and dispose of with care.

3.  The product you have purchased is intended only for growing plants and should only be used for this purpose. When used for other purposes we will take 

no responsibility.

4. It is recommended that this greenhouse is assembled by two people.

5.  Should you encounter difficulties constructing this house, or in fitting the glass or polycarbonate sheets, please contact your retailer 

 

– 

do not use force!

6. The greenhouse must always be anchored.

safety Warning

EN

050.01.1603

Summary of Contents for IDA 5200

Page 1: ...050 01 1603 Ida Iris 5200 6500 7800 Assembly instructions DA SV Montagevejledning Monteringsanvisning EN DE NL Montageanleitung Montage Instructies...

Page 2: ...60000 68000 76000 1x 1x 1x 1063 6 635 1x 2x 2x 1064 6 602 1x 2x 2x 1065 6 520 2x 4x 4x 1066 6 602 1x 2x 2x 1067 6 295 1x 2x 2x Item No Part Sect Ref Size mm Quantity per 5200 6500 7800 1092 1 2 120 8x...

Page 3: ...3106 3728 1x 1x 1x 4232 1 2 1670 7x 8x 9x 4233 1 2 1716 5 4x 4x 4x 4236 1 1670 2x 2x 2x Item No Part Sect Ref Size mm Quantity per 5200 6500 7800 4237 2 2035 1x 1x 1x 4238 2 2035 1x 1x 1x 4241 2 314 1...

Page 4: ...section 5A Two single doors on both sides is indicated by SDS Please decide at this point how and where you wish the doors to be assembled and follow the appropriate diagram Note The fields on both s...

Page 5: ...bottom bar 1066 using screws 1006 6 8 Place the plastic cap 1019 over the end of the window opener 6 6 and connect both window fixers 2016 onto the window sill 1063 using screws 1006 6 8 Position the...

Page 6: ...Achtung Die Felder auf beiden Seiten einer T r ffnung ben tigen ein Horizontalprofil 1 6 1 9 2 Seitenw nde Verschrauben Sie die Wandprofile 4248 4249 mit den Bodenprofilen 5546 2 1 und Quer streben 42...

Page 7: ...t den Seitenrahmen verschrauben Achtung Das Fenster muss rechtwinklig sein Den Dachfensteraufsteller 1067 mit dem unteren Fensterprofil 1066 verschrauben Hierbei werden die Schrauben 1006 verwen det 6...

Page 8: ...of voorkant van de kas twee losse deuren worden gemonteerd Zie paragraaf 5A De aanduiding voor twee losse deuren aan beide kanten is SDS Beslis op dit punt a u b hoe en waar u de deur gemonteerd wilt...

Page 9: ...echt zit alvorens alle boutjes aan te draaien Bevestig de raamopener 1067 met het on derprofiel 1066 door middel van schroeven 1006 6 8 Bevestig beide raamuitzetpinnen 2016 op het kalfje 1063 door mid...

Page 10: ...og 2 5 Sp nd begge de samlede sider l st sammen med den tidligere samlede front og monter samtidigt skr stivere 4233 se 2 4 2 6 og 2 7 og hvis p kr vet ogs de vandrette af stivningsprofiler 2096 2097...

Page 11: ...astlister 6600 se 7A 2 For yderligere at vindsikre polycarbonatpla derne anbefales det specielt i vindudsatte om r der at sikre polycarbonatpladerne ved at fastg re dem ved hj lp af selvsk rende skru...

Page 12: ...n inklusive de diagonala str vorna 4233 2 4 2 6 2 7 och om n dv ndigt f rst rkningar 2096 2097 f r d rrarna F st takets gavelprofil 4237 4238 l st mellan de bakre lodr ta stolparna 4248 4249 och frams...

Page 13: ...och skjut den till nskat l ge 6 6 F st f nsterkarmen 1063 med hj lp av de tidigare if rda bultarna i de mellanliggande profilerna 4255 mellan dessa och f rst rknin garna 4270 med mutter 6 6 och 6 7 Ko...

Page 14: ...14 Ida 5200 6500 7800 0 0 050 01 1603 5200 6500 7800 A 1901 mm 1901 mm 1901 mm B 2544 mm 3166 mm 3788 mm A B X X 30 mm 30 mm 30 x 20 mm...

Page 15: ...x 2x 2x 2x 2097 2x 1x 1x 3094 1x 3097 1x 4227 1x 1x 1x 1x 4232 2x 3x 3x 3x 4233 2x 2x 2x 2x 4236 2x 2x 2x 2x 2046 1 4 4232 1 5 1 7 4233 2097 3094 1092 4233 4236 4227 4227 1 1 1 2 1 3 1 4 1 5 1 6 1 8 1...

Page 16: ...7 3094 2097 3094 DD1 DD2 SD1 SD2 SDS 1001 23x 23x 26x 26x 20x 1002 23x 23x 26x 26x 20x 1092 2x 2x 2x 2x 2x 2092 2x 2x 2x 2x 2x 2097 1x 1x 2x 3094 1x 1x 3097 1x 1x 4222 1x 1x 1x 1x 1x 4228 1x 1x 1x 1x...

Page 17: ...x 1x 3094 1x 1x 3097 1x 1x 4223 1x 1x 1x 1x 1x 1x 4229 1x 1x 1x 1x 1x 1x 4232 4x 4x 4x 5x 5x 5x 4233 2x 2x 2x 2x 2x 2x 4236 2x 2x 2x 2x 2x 2x 4296 1x 1x 1x 1x DD1 SD1 SD2 DD2 1 9 4232 3094 3097 1 1 1...

Page 18: ...1x 1x 4261 1x 4262 1x 5546 2x 2 6 2 7 2 2 2 3 2 5 2 1 2 8 2 9 2 10 2 6 2 12 2 7 2 4 2 5 SDS 2 x 5A 5BL R 5546 4249 4249 4262 2 11 4249 4262 4262 4232 4261 4227 4228 4229 1092 4233 4236 1092 4237 5546...

Page 19: ...5 4266 5BL R 5BL R 2 x 5A 3 4 3 6 3 5 3 8 3 10 3 4 3 11 3 7 3 5 3 6 5BL R 3 9 4255 4270 4255 4270 4255 4270 4255 4270 4255 4270 4264 4265 4266 4237 4264 4265 4266 4237 4251 4252 4253 4255 1001 4255 42...

Page 20: ...Ida 5200 6500 7800 1 4 20 050 01 1603 4 1 4 2 4251 4252 4253 4248 4249 4 1 4 2 4251 4252 4253 4249 4248...

Page 21: ...2x 2 1362 1x 2 1500 2x 2 1515 2x 2 3021 2x 2 4059 2x 2 2x 5 1 1014 1003 5 2 1361 1359 1362 1360 5 4 5A 8 1360 5 2 1361 1003 5 2 5 1 5 6 5 9 5A 3 1001 1002 1003 1362 1359 5 4 1362 1304 1015 1009 1007 3...

Page 22: ...5 1x 2006 2x 3021 1x 4059 1x 4098 1x 5BL 3 4238 1347 1015 4227 4228 4229 5BL 3 1001 1002 1003 1362 1359 5 1 1014 1003 5 2 1361 1359 1362 1360 1360 5 2 1361 1003 5 2 5 1 5 6 5 9 5 4 1362 1304 1015 1009...

Page 23: ...01 1x 3021 1x 4059 1x 4099 1x 5 1 1014 1003 5 2 1361 1359 1362 1360 1360 5 2 1361 1003 5 2 5 1 5 6 5 9 5BR 3 1001 1002 1003 1362 1359 5 4 1362 1304 1015 1009 1007 3021 5 5 5 6 1515 1500 3021 5 5 5 9 1...

Page 24: ...1 1x 2 1x 2 1064 1x 1 1x 2 1x 2 1065 2x 1 2x 2 2x 2 1066 1x 1 1x 2 1x 2 1067 1x 1 1x 2 1x 2 2016 1x 1 1x 2 1x 2 1063 2016 1006 1065 1001 1019 1067 6 1 6 2 1066 1065 1064 3 D 1065 Art No 3 Art No D mm...

Page 25: ...x 2x 5 3679941 612 x 317 165 2x 2x 2x 6 3679951 612 x 162 10 2x 2x 2x Total 41x 46x 50x 1012 5200 6500 7800 1011 158x 170x 182x 1012 32x 36x 40x 1020 1x 1x 1x 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1...

Page 26: ...11 1020 1020 7B 1 No 4mm PC No 6mm PC mm E3mm 5200 6500 7800 A 369867 369967 610 x 1656 8x 9x 10x B 369968 6mm 369968 610 x 2030 3x 3x 4x C 369969 6mm 369969 610 x 1484 1x 2x 2x D 369430 369430 600 x...

Page 27: ...7 050 01 1603 1006 4x 1402 6x 1403 4x 1408 2x 1413 2x 1416 2x 1417 2x 8 8 1 8 2 8 3 8 4 8 3 8 5 8 6 8 1 8 2 1408 4264 4265 4266 1408 1417 1402 1416 1402 1402 1413 1403 1006 8 5 8 4 8 5 8 6 1403 8 6 10...

Page 28: ...mund Postfach 170163 44060 Dortmund Deutschland Tel 49 231 941655 0 Fax 49 231 941655 99 www eph schmidt de verkauf eph schmidt de OPJ A S Volderslevvej 36 A 5260 Odense S Danmark Tel 45 66 15 10 30 F...

Reviews: