2
1
2
1
54
Firing temperature and holding time
6. Button management
7. Firing window
8. Technical data / information
Modifiable parameters:
•
Firing chamber temperature: pre-drying temperature plus 10°C – 1200°C
•
Holding time: 00:00 min – 60:00 min
Note:
•
The possible values to enter are displayed above the number field.
•
For the two-stage firing curve, the same procedure applies to the program values in the second rise time
for entering and changing the values.
•
For reliable firing results with a good degree of gloss and correct color reproduction.
Cooling temperature
Modifiable parameters:
•
Cooling temperature: 60°C – 900°C, or holding temperature minus 10°C
•
Entered value 0 – 60:00 min
Note:
•
The "Activate cooling" button is automatically activated when the temperature or time is entered
and must then be pressed. The possible values to enter are displayed above the number field.
•
Deactivate cooling: Press "Activate cooling" button.
•
For slow cooling of the restoration to prevent thermal stress on the material.