![Visual Productions IoCore2 User Manual Download Page 59](http://html1.mh-extra.com/html/visual-productions/iocore2/iocore2_user-manual_1034070059.webp)
Feature
Function
Parameter 1
Parameter 2
Playstate
Start
Timer #
-
Playstate
Stop
Timer #
-
Playstate
Restart
Timer #
-
Time
Set
Timer #
Time
B.11
UDP
Send an UDP message via the network. Specify the recipient in Parameter 2.
For example ”192.168.1.11:7000”.
Feature
Function
Parameter 1
Parameter 2
Send Float
Set
floating point number
IP address & port
Send Float
Control
-
IP address & port
Send Unsigned
Set
positive number
IP address & port
Send Unsigned
Control
-
IP address & port
Send Bool
Set
true or false
IP address & port
Send Bool
Control
-
IP address & port
Send String
Set
text string
IP address & port
Send String
Control
-
IP address & port
Send String Hex
Set
hex string
IP address & port
Send String Hex
Control
String
IP address & port
Wake On Lan
Set
MAC Address
IP address & port
Please note that string in parameter 1 has a maximum length of 25 charac-
ters.
The Send Bytes features allows for sending ASCII codes. For example, in or-
der to send the string ’Visual’ followed by a line feed parameter 1 should be
’56697375616C0A’.
When using the Wake On Lan feature parameter 1 should contain the MAC
Address of system’s NIC (Network Interface Controller) you wish to wake up.
The recommended value for parameter 2 is
255.255.255.255:7
. This broad-
casts the message to the whole network at port 7 which is most commonly used
for Wake On Lan.
B.12
Variable
Manipulate one of the eight variables.
59