NTCS
April 2018
Visual Engineering
Video solutions. Integrated
visualengineering.co.uk
Page 12
Item
Description
1 DHCP Enable
Check this box if you need the Mesh node to obtain its IP address remotely from
a DHCP server.
2 IP Address
Complete this box to give the Mesh node a fixed IP address when DHCP is not
used, it is not used by default.
3 Operating Mode
This should be set the same for every node in the mesh and is defaulted to ’16
node HiRate’.
The Status Tab
Item
Options
Notes
1 Node ID
0 to 11 or 0 to 15
We are showing two Node IDs, 1 and 2. There could be
up to sixteen nodes in a mesh, numbered 0 to 15.
2 Unit Name
You can use up to
12 alphanumeric
characters for the
Unit Name
The Unit Name is a friendly name to make it easier to
identify each camera node. This name is assigned in the
Global Settings Tab.
3 IP Address
192.168.1.180 for
example
This shows the IP address of the unit that we set up
in our initial configuration. Notice that it is shown as a
hyper-link. If you click on one of these hyper-links the
browser will switch to that node.
4 Battery Voltage
0 to 16v
This returns the current input voltage of the node. The
voltage should show approximately 12v.
5 Occupancy
Blue and Orange
Bars
The blue bar gives a visual indication of the volume of
data generated by this node. An orange bar gives a visual
indication of the volume of data passing through this
node.
6 Show Details
Check box
Displays network information about IP packets etc.
This displays detailed
status information
of received signal
quality and enables
navigation between
nodes. The Status tab
is divided into three
sub-tabs:
•
Overview
• Spectra
• Maps
1
2
3
4
5
6