VISTEON AUXILIARY IDLE Operating Instructions Manual Download Page 9

Page  8

Section 3.4  CUSTOM RPM CONTROL

Custom RPM Control allows the user to elevate and adjust the engine speed from a remote location on the
vehicle.

 

Inputs are provided in the wiring harness for an electrical vernier potentiometer-type input.   Correct installation
and programming is required for proper operation.  Before beginning Custom RPM Control, follow the instructions
given in Section 6, "Remote Switch Installation and Usage" for the proper installation of the remote switches.

Also read and understand the specifications in Section 9, for the proper transfer function for custom input voltage
to engine speed RPM output.  For additional programming options, refer to Section 5 of this manual.

Step 1  Program the module for Custom RPM Control.

1. Go to main programming mode, press and hold [RPM CONTROL], [CHARGE PROTECT] & [FORD]

keys

2. Go to Menu 5 by pressing the [FORD] key four (4) times. 
3. Change the mode from "Base" to "

Cust

" by pressing any [ARROW] key.

4. Save and exit programming mode by pressing the [FORD] key.

Step 2  Initiate Custom RPM Control.

• 

The 

RPM Control light will turn on steady

 when Custom RPM Control mode is programmed.

» RPM value associated with the Custom Input Voltage is displayed

⇒ 

If within range (0.5 to 4.5 Volts), display shows value of engine speed for input
voltage.

⇒ 

If input is above or below voltage range, display shows OFF

Step 3  Activate Custom RPM Control.

• 

Press 

 [FORD]

 key or installed Remote FORD switch to activate Custom RPM Control mode

» RPM Control Light will flash
» Engine idle is elevated to the RPM value associated with input voltage
» Current engine speed is displayed

Step 4  As desired, adjust idle speed manually.

• 

As input voltage is adjusted, engine speed value adjusts accordingly.

Exiting Custom RPM Control

ANY ONE of the following will exit Custom RPM Control and return engine to normal idle.

• 

Press  Remote FORD switch *

• 

Press  [FORD] key *

• 

Press  [POWER]  key

• 

Press  [RPM CONTROL] key **

• 

Out-of-Range Custom Voltage Input (<0.5V or  >4.5V)

• 

Press brake or clutch pedal, take vehicle out of park, or release parking brake

*  If [FORD] keys are pressed again, the vehicle will re-enter Custom RPM Control mode.

** Pressing the [RPM CONTROL] key will return to Basic RPM Control mode (Section 3.1) until next run cycle.

Summary of Contents for AUXILIARY IDLE

Page 1: ...INSTRUCTIONS for the AUXILIARY IDLE CONTROL MODULE Exclusively for Ford Trucks with 7 3L DIT Diesel Engines Powertrain Control Systems Division Visteon Automotive Systems Copyright 1998 Part No XC3F...

Page 2: ...10 14 4 1 Basic Operation 10 4 2 PTO Lower Limit Engagement 11 4 3 PTO Upper Limit Overspeed 12 4 4 PTO Linked with RPM Control 13 4 5 PTO Linked with Custom RPM Control 14 5 Programming the APCM Modu...

Page 3: ...and Manual RPM Adjustment Arrows Each arrow key contains a preset speed allowing four 4 programmable RPM settings The arrow keys are also used to manually increase or decrease the engine speed at a fa...

Page 4: ...L MODE Section 3 PTO RPM CONTROL LINKED Section 4 4 Custom RPM Section 4 5 REMOTE RPM CONTROL SWITCH Operation Section 3 Installation Section 6 REMOTE CHARGE PROTECT SWITCH Operation Section 2 Install...

Page 5: ...arge Protection Press CHARGE PROTECT key A Charge Protect Light will flash Engine speed will increase to a variable RPM dependent on the battery voltage requirement Nominal system voltage will be disp...

Page 6: ...ic Charge Protection completely you will need to re program the APCM Step 1 Section 2 3 REMOTE USAGE CHARGE PROTECTION For this module an input is available to allow remote activation and deactivation...

Page 7: ...CONTROL key on module RPM Control Light will turn on RPM value stored in Memory 1 is displayed If desired select another RPM memory setting by pressing any ARROW key RPM value stored in the Memory se...

Page 8: ...ic Charge Protection and return engine to normal idle Press FORD key B Press RPM CONTROL key Press POWER key Press brake pedal take vehicle out of park or release parking brake If toggled again the ve...

Page 9: ...Step 2 Initiate Custom RPM Control The RPM Control light will turn on steady when Custom RPM Control mode is programmed RPM value associated with the Custom Input Voltage is displayed If within range...

Page 10: ...shows the RPM value associated with the Custom input voltage If OFF is displayed the voltage input is not within 0 5 4 5V range The engine speed will be elevated within a few seconds after vehicle s...

Page 11: ...ng diagram shows how the upper and lower PTO speed limits function when programmed Section 4 1 BASIC OPERATION OF PTO CONTROL The PTO CONTROL key works like a on off switch Press the key once to turn...

Page 12: ...ith the ARROW keys to the desired maximum engagement speed for PTO mode 4 Save and exit programming mode by pressing the FORD key Step 2 Activate the PTO Control output Press PTO CONTROL key on the mo...

Page 13: ...with ARROW keys to the desired maximum allowable engine speed for PTO mode 4 Save and exit programming mode by pressing the FORD key twice Step 2 Activate the PTO Control output Press PTO CONTROL key...

Page 14: ...ey 5 Press Ford key Menu 3 shows the programmed PTO Lower Limit 6 Press Ford key Menu 4 shows the programmed PTO Upper Limit 7 Menu 5 should be set to BASE mode Press Ford key to exit NOTE Automatic R...

Page 15: ...to exit NOTE Automatic RPM Control is not available with PTO RPM LINKED Step 2 Initiate PTO Linked with CUSTOM RPM CONTROL mode The RPM Control light will turn on steady automatically when Custom RPM...

Page 16: ...OFF Initial Ramp Rate is set to 500 RPM second displays 88 on screen Section 5 2 APCM MAIN PROGRAMMING MODE The required programming steps for each of the module functions is covered in each respectiv...

Page 17: ...ey to select options in each Menu To exit programming mode complete all menus OR press and hold the RPM CONTROL CHARGE PROTECT and FORD keys for 3 seconds CHARGE RPM RPM V PTO RPM V PTO PTO RPM RPM RP...

Page 18: ...you for example a slow rate of increase for clutch durability or a fast rate for time efficiency The second menu allows the initial ramp up rate to be modified The up ramp rate is how fast the engine...

Page 19: ...itches for all exterior applications Section 6 1 REMOTE INPUT SWITCHES Section 6 1 1 Remote Switch Installation For Remote RPM Control Remote Charge Protection use Momentary Contact push button switch...

Page 20: ...PM value corresponds to what custom input voltage V refer to Section 9 For Remote Custom RPM Control Connect potentiometer to red VREF output black SIG RTN pink CUSTOM input The Custom Input Voltage s...

Page 21: ...M signal on off 4 White Purple SCP Bus Twisted Pair Connects to Vehicle 5 Black Signal Return Use for Remote Custom Input 6 Black Ground Connects to Vehicle 7 Gray Remote RPM Control Input Use for Rem...

Page 22: ...are ok replace APCM 6 Display reads EErr APCM component defective replace APCM 7 Display reads AErr APCM component defective replace APCM 8 Must press remote switch twice to activate RPM Control May h...

Page 23: ...mum RPM for Charge Protection 1100 RPM 1998 MY Econoline 1200 RPM 1999 MY F Series 1300 RPM All previous Model Years for E F Series Maximum charge rate 2500 RPM RPM CONTROL MODE Selectable high idle o...

Page 24: ...Part No E8EB 14A464 BZA BUS TAN ORANGE BUS PINK LIGHT BLUE KEY POWER F Series RED YELLOW E Series RED LIGHT GREEN GROUND BLACK Module Side Ford Part No F3LB 12624 ZB BUS RED BLUE BUS WHITE PURPLE KEY...

Page 25: ...t ramps up to the desired elevated idle at a rate of 500 RPM second The down ramp rate RMP should remain at I 100 RPM sec or lower Table 9 3 2 Engine Speed Ramp Rates Ramp Rate Setting Ramp Rate LCD D...

Reviews: