![vistaCNC P2-S Manual Download Page 5](http://html1.mh-extra.com/html/vistacnc/p2-s/p2-s_manual_1033745005.webp)
www.vistacnc.com
- 5 -
www.vistacnc.com
- 5 -
iMach
III
P2-S Pendant Manual v. 4.0.0
2.1
STEP, STEP SIZE and STEP JOG RATE
mode
2.1.1
STEP
In STEP mode, the selected axis moves 1 step at each MPG click (detent) with the step
size currently in the system and with speed of step jogging rate.
□
Selected axis name. It flashes at ½ second rate.
□
Step jogging rate in units/minute,
□
Step size. The step size and rate display changes
alternately every 2 seconds
2.1.2
STEP SIZE
While pressing and holding the EN side button , turn MPG one or few
clicks clockwise or counterclockwise to select predefined step size.
Different step sizes can be set up in PlugIn Configuration table.
Other step size can be set directly on Mach3 screen
2.1.3
STEP JOG RATE
While double clicking (press, release, and press, within half a second)
and holding the EN side button , turn MPG to change step jogging rate.
□
Percentage of the maximum axis velocity.
□
Feedrate used in step jogging