32
QNVR_PoE 4 and 8 channel manual V1.0
QVNR04P/08P installation and user manual
2-3. Alarm
This configures the various recording settings per channel in the alarm record mode.
There are 4 sensor inputs on the rear of the NVR, these can be used to initiate the alarm
record mode.
The stream, audio are set up in the same way as the normal recording.
[ Preset on Alarms ]
You can enable PTZ camera to move to a preset position when a sensor alarm occurs.
A Single Alarm input can be used to drive up to 4 PTZ cameras to preset positions or Preset
tours. Click the Set icons below the Preset On Alarms
label.
Select the operation(preset or tour) of
each PTZ camera when the alarm
occurs.
The sensor inputs on the rear panel
can be configured to be normally open
(N.O), normally closed (N.C) or None.
Note
:
This function is only available
when RS485 telemetry formats are
being used.
Alarm Timer
This allows you to set the duration time
of alarm;
- Acknowledge: You can stop the alarm
by clicking the mouse.
- Time out: The alarm stops over time.
- Transparent: The alarm stops by the
condition of sensor.
Keyswitch
A single alarm input can be selected to
be a control switch, to turn alarm on or
off globally. This allows a final exit key switch to be used to manually arm the inputs.