VISSONIC Electronics Limited
Page 13
Voice
Apply
Voice control
Request
Mode
Description
Override
In the Override mode, the delegate unit turns on or off the microphone directly via
the microphone on/off button. When the number of enabled delegate units reaches
the maximum, the unit that turns on the microphone earliest will be automatically
turned off if the next delegate unit turns on the microphone.
Open
In the Open mode, the delegate unit turns on or off the microphone directly via the
microphone on/off button. When the number of enabled delegate units reaches the
maximum, the delegate unit to be turned on next will be added to the waiting list
and enter the waiting state until any enabled unit turns off the microphone.
Voice
In the Voice mode, the delegate unit controls the microphone by intelligently
recognizing the nearest human voice. When the microphone detects the nearest
voice source, it will immediately turn on automatically. When the number of
enabled delegate units reaches the maximum, the unit that turns on the microphone
earliest will be automatically turned off if the next delegate unit turns on the
microphone. (For special requirements, 20 microphones can be turned on freely.)
Apply
In the Apply mode, the delegate unit requests to turn on the microphone through the
microphone button. In the request status, the LED of the conference unit is green.
The chairperson presses the agree button
or reject button
to decide
whether a delegate unit can turn on the microphone. When the maximum number of
speech delegates is reached, the system allows the same number of delegate units to
enter the waiting list.
Active MIC (maximum number of microphones)
On the home screen, you can press the "
△
" button to quickly enter the screen for setting the maximum number of
microphones allowed.
Menu
Parameter
Description
Active MIC
1, 2, 4, 6
Limits
the
number
of
delegates'
microphones
allowed to be turned on.
Monitoring information (displaying unit connection)
Menu
Parameter
Description
UNIT
0000 - 4000
Displays the number of
conference
microphones
connected to the system, and
monitors
the
connection
status of the system in real
time for timely detection of
unit failures and connection
failures.