background image

 

5

radiator, etc.). Direct sunlight may affect the acrylic coating and heat sources may increase 
electrical consumption. Extreme cold ambient temperatures may also cause the Beer 
Dispenser not to perform properly.

 

This unit is not designed for outside installation (ie 

garages, porches, etc.) 

  Avoid locating the Beer Dispenser in excessive humidity. 

  Plug the Beer Dispenser into a dedicated, properly installed-grounded wall outlet. Do not 

under any circumstances cut or remove the third (ground) prong from the power cord. Any 
questions concerning power and or grounding should be directed toward a certified electrician 
or an authorized service center. 

  After plugging the appliance into a wall outlet, allow the unit to cool down for 2-3 hours before 

placing any contents in the Beer Dispenser compartment. 

 

 

 

 

 

 

 

 

 

 

 

¾

 

Electrical Connection 

 

 
 
 
 
 

This Beer Dispenser should be properly grounded for your safety. The power cord of this Beer 
Dispenser is equipped with a three-prong plug which mates with standard three prong wall outlets to 
minimize the possibility of electrical shock. 
 
Do not under any circumstances cut or remove the third ground prong from the power cord supplied. 
 
Use of extension cords is not recommended. 
 
This Beer Dispenser requires a standard 115/120-volt, 60Hz electrical outlet with three-prong ground 
receptacle. The cord should be secured behind the Beer Dispenser and not left exposed or dangling 
to prevent accidental injury. 
 
Never unplug the Beer Dispenser by pulling the power cord. Always grip the plug firmly and pull 
straight out from the receptacle. 
 

WARNING 

CO

2

 GAS CAN BE DANGEROUS 

 

WARNING

: CO

2

 cylinders contain high-pressure compressed gas which can be hazardous if not 

handled properly. Make sure you 

READ

 and 

UNDERSTAND

 the following procedures for CO

2

 

cylinders 

BEFORE INSTALLATION

1. 

ALWAYS

 connect the CO

2

 cylinder to a regulator. Failure to do so could result in explosion 

with possible injury when the cylinder valve is opened. 

2. 

NEVER

 connect the CO

2

 cylinder directly to the product container. 

3. 

ALWAYS

 follow correct procedures when cylinders are changed. 

4. 

ALWAYS

 secure the cylinder in an upright position. 

5. 

NEVER

 drop or throw a CO

2

 cylinder. 

6. 

ALWAYS

 keep a CO

2

 cylinder away from heat. Store extra cylinders in a cool place 

(preferably 70°F). Securely fasten with a chain in an upright position when storing. 

7. 

ALWAYS

 ventilate and leave the area immediately if CO

2

 leakage has occurred. 

8. 

ALWAYS

 check the D.O.T. test date on the cylinder neck before installation. If over five (5) 

years, do not use, return cylinder to gas supplier. 

9. 

NEVER

 connect a product container unless there are two (2) safety’s in the pressure system: 

a.  One at or on the CO

2

 regulator 

b.  One at or on the product coupler or in the pressure gas line. 

a

Warning

a

 

Improper use of the grounded plug can result in the risk of electrical shock. If the power cord is 
damaged, have it replaced by an authorized service center. 

Summary of Contents for Vissani MCKC490S

Page 1: ...1 4 9 CU FT BEER KEG COOLER INSTRUCTION MANUAL Model No MCKC490S To ensure proper use of this appliance and your safety please read the following instructions completely before operating this appliance ...

Page 2: ...r Beer Keg_______________________________ 6 9 Dispensing of Beer _________________________________________________ 9 Operating Your Beer Dispenser______________________________________ 10 Setting the Temperature____________________________________________ 10 Automatic Defrosting ______________________________________________ 10 Converting to an All Refrigerator ____________________________________...

Page 3: ...er 2 Plastic Gasket 3 Safety Guard Rail 4 Drip Tray 5 Adjustable Thermostat 6 CO2 Regulator 7 CO2 Gas Cylinder 8 CO2 Gas Cylinder Support 9 Evaporator 10 Reversible Door 11 Beer Keg not included 12 Metal Plate 13 Metal Washers 2 14 Castors with Lock 4 ...

Page 4: ... unit The fumes can create a fire hazard or explosion Save these instructions INSTALLATION INSTRUCTIONS Before Using Your Beer Dispenser Remove the exterior and interior packing Check to be sure you have all of the following parts 1 Safety Guard Rail 1 Drip Tray 2 Pieces 1 CO2 Cylinder Support 1 CO2 Regulator Box 1 CO2 Empty Cylinder Box 1 CO2 Air Line Hose Red 1 Beer Keg Coupler Box 1 Beer Tower ...

Page 5: ...eer Dispenser and not left exposed or dangling to prevent accidental injury Never unplug the Beer Dispenser by pulling the power cord Always grip the plug firmly and pull straight out from the receptacle WARNING CO2 GAS CAN BE DANGEROUS WARNING CO2 cylinders contain high pressure compressed gas which can be hazardous if not handled properly Make sure you READ and UNDERSTAND the following procedure...

Page 6: ...tallation Sketch Install the four castors with lock provided into the unit s bottom four screw holes pre supplied The two metal gaskets are used for the front two Castors Figure 1 before installation Figure II is the final version I II Metal Washers ...

Page 7: ...e Hose To Regulator Attach the open end of the red hose to the hose barb connection on the regulator Secure hose by using one clamp provided Use pliers screwdriver to tighten clamp to prevent leaks See Figure 3 Installation Of The Beer Tower Remove the top plug by twisting and pulling out saving it for later use if you decide to convert unit to an all refrigerator unit Unravel the beer line clear ...

Page 8: ...ler turning until tight How to Tap a Keg of Beer Make sure that the CO2 is turned off and the Secondary valve on the regulator is in the Closed position Pull out and release the pressure release valve on the Coupler to purge any air pressure Make sure the beer tower faucet is in the closed position Pull tapping handle out and press downward until it locks into position See Figure 8 The keg is now ...

Page 9: ...R Keep beer keg refrigerated at all times Never allow beer lines to dry out Use clean beer glassware before pouring Hold glass at a 45 angle when 2 3 full start to straighten glass as the glass fills Always make sure the faucet handle is pushed all the way back Note Keg sizes that can be used in your beer dispenser 1 2 barrel 59 Liters 15 5 gals 1984 oz 164 12 oz Glass 1 4 barrel 30 Liters 7 8 gal...

Page 10: ...75 F The more beer there is the longer it will take to cool down Automatic Defrosting There is no need to defrost the Beer Dispenser Defrost water collects and passes thru the drain outlet in the rear wall into a tray located above the compressor where it evaporates Converting To An All Refrigerator 1 Turn off the control knob to the OFF position 2 Close the main valve on the CO2 cylinder 3 Close ...

Page 11: ... the left or right side The unit is delivered to you with the door opening from the left side To reverse the opening direction please follow the instructions below Caution To avoid personal injury to yourself and or property we ecommend that someone assist you during the door reversal process ...

Page 12: ...ent Rinse well and wipe dry with a clean soft cloth Vacation Time Short vacations Leave the Beer Dispenser operating during vacations of less than three weeks Long vacations If the appliance will not be used for several months remove all contents and unplug the power cord Clean and dry the interior thoroughly To prevent odor and mold growth leave the door open slightly Moving Your Beer Dispenser R...

Page 13: ...t correctly The door gasket does not seal properly The unit does not have proper clearance Vibrations Check to assure that the Beer Dispenser is level The Beer Dispenser seems to make too much noise The rattling noise may come from the flow of the refrigerant which is normal Gurgling caused by liquid refrigerant cycling is normal Contraction and expansion of the inside walls may cause popping and ...

Page 14: ...e evaporator system due to improper defrosting of the unit Repairs performed by unauthorized service agents Service calls that do not involve defects in material and workmanship such as instruction on proper use of the product door reversal or improper installation Replacement or resetting of house fuses or circuit breakers Failure of this product if used for other than for its intended purpose Di...