background image

play it smart

Xero Twin P/L

Assembly and operating instructions

USA & CANADA

Summary of Contents for Xero Twin P/L

Page 1: ...play it smart XeroTwinP L Assembly and operating instructions USA CANADA ...

Page 2: ... most pronounced more so than with front on horizontal or inclined pole displays where garments are hung side on such that hangers have to be moved more frequently To prevent garments from becoming soiled cleaning of the hanging rods is essential This abrasion can be considerably reduced by using a coat hanger cover scliss 929 449 02 No responsiblity can be accepted for damage caused by soiling as...

Page 3: ...on is the shortening of profiles from the upper side The safety instructions of the assembly instructions must be followed as well as the instructions on the labels of the individual parts The indicated nominal current A may not be exceeded In event of improper use or cleaning with liquids a risk of an electric shock exists due to possibly exposed live parts Always disconnect from power before cle...

Page 4: ... L 500 mm 19 685 1 2019 US Check the power consumption of electrical appliances The maximum power consumption should be 10 below the nominal power of the converter Visplay connection system Powering with 90 W converter Dimensions of the 90 W converter 1 24 V distributor 6 way optional 2 90 W LED converter ...

Page 5: ...he bottom of the power supply before the profile is installed to the panel 2 Assembly dimensions Layout Xero Twin P L Aluminium profiles can be screwed on panels or various substructures on the wall The accessories from Xero Twin P L and Xero 8 can be used Assembly in wooden panels Please observe the indications concerning weight loads and ensure that the substructure of the wall units furniture a...

Page 6: ...098 A 637 5 25 098 A 1262 5 49 705 A 637 5 25 098 A 637 5 25 098 1 2 3 3x 929 226 21 170 6 693 1 2019 US Assembly dimensions Xero Twin P L profile screwed on to substructure and rear panels attached from the front fixed axis distance Recommendation for profile axis with Xero Twin P L and Xero 8 accessories Inserting the panels into Xero Twin P L profile Fixed axis distance Merchandise suports are ...

Page 7: ...non powered profile Depending to your local regulations a conduit must be used for the primary side of the driver Check this before installation It must be ensured that access to the driver is possible for inspection and subsequent servicing Dimensions and distances of holes All fastening points have to be used in event of maximum loads The electrical components and the end cap must be removed bef...

Page 8: ...eep and max 12 W power consumption For wooden shelf max 650 mm 25 591 long by max 356 mm 14 016 deep and max 6 W power consumption Production drawings of wooden shelves are available for downloading on www visplay com or can be received on request Drawing no 229 120 Production drawings of wooden shelves are available for downloading on www visplay com or can be received on request Drawing no 252 8...

Page 9: ...ll as the fastening material used All fastening points have to be used in event of a maximum weight load Please also observe the weight loads indicated in our sales documentation Attaching the glass shelf The merchandise support has a slight slope approx 2 Max load Profile per 1000 mm 40 220 lbs Glass shelf with without LED lighting 55 lbs Brackets with without single power adapter 24 V for wooden...

Page 10: ...m Russia Distributed by ULTIMATHULE Exclusive Dealer Business quartel ARMA Nizhniy Susalniy per 5 bld 18 105065 Moscow Russia T 7 495 988 21 20 visplay ultimathule ru Saudi Arabia Distributed by Saudi TKT Authorized Distributor P O Box 10700 Jeddah 21443 Saudi Arabia T 971 4 321 56 74 visplay dubai visplay com Turkey Distributed by Dekotek Mimarlık Ltd Sti Exclusive Dealer Sair Nigar Sokak 80 8 Os...

Reviews: