Installation Notes:
The top cover should only be accessed by authorized service personnel or manufacturer. Do not obscure the detector field of view with large objects.
Install in position such that expected intruder motion is perpendicular to the zones of detection.
Alarms triggered by conditions such as weather, blowing leaves and brush, or related environmental conditions, etc., need to be considered when
assessing the installation and application. It is recommended that the intrusion detection unit is not to be connected to an alarm initiating circuit but may
be connected to a trouble alarm circuit if nuisance trips are not tolerable.
COVER CLOSURE
1.
Release locking
2.
Adjust
3.
Lock
4.
Release locking
5.
Adjust
6.
Lock
7.
Turn cover and push slider
8 & 9.
Put back cover
10.
Secure with screw
A.
Vertical angle steps
Figure 3 - Adjustment and Cover Closure
2.2. Battery Insertion
It is recommended to perform the first batteries insertion on a flat surface (see
Figure 4
). After battery insertion, the LED will flash for 60 seconds and
then the detector will enter a 15 minutes' local diagnostic mode.
D-304493 TOWER CAM PG2 Installation Instructions