background image

D-304493 TOWER CAM PG2 Installation Instructions

1

1. INTRODUCTION

The TOWER CAM PG2 is a 2-way, wireless outdoor digital mirror PIR detector
with built-in camera. Activated upon PIR detection or upon demand, the
TOWER CAM PG2 sends clear images to the Monitoring Station for alarm
image verification.

The PIR motion detector’s features are as follows:

l

Operates with PowerMaster control panels (version 18 and higher)

l

Patented 8 independent quad PIR detectors (Octa-QUAD

) operating in

true Quad configuration (patented) with true motion recognition (TMR)
processing for each of the 8 PIR detectors.

l

Advanced Obsidian Black Mirror

TM

optics (patent pending).

l

Optimum performance even in poor weather conditions such as snow, rain,
dust, wind and direct sunlight

l

Tamper protection prevents opening and removal from wall

l

PowerG two-way Frequency Hopping Spread Spectrum

FHSS-TDMA

technology

- provides robustness and reliability

l

Built-in link quality indicators enable installer to check signal quality without
physically approaching the control panel.

l

Robust housing with recessed window.

l

Smart anti masking distinguishes between masking spray and rain.

l

Alarm LED is visible in sunlight.

l

Automatic termination of walk-test after 15 minutes.

l

Microprocessor-controlled temperature compensation.

l

Immunity to pets weighing up to 18 Kg (40lb) – see Table 1

l

Built-in swivel bracket

The camera’s features are as follows:

l

Up to 10 cameras can be enrolled

l

Images multiplexed from all enrolled cameras

l

Color and black & white images

l

Auto-setup

l

Camera tuning by simple walk-test

l

Day and night CMOS camera, with near IR illumination. This allows taking
pictures in full darkness without letting the intruder know.

l

Instant capture: guarantees capture of fast moving intruder.

l

Optional AC power

l

An event records 2 images per second. 10-15 images total

Notes:

1.

For UL/ULC installation, the camera feature is not to be enabled in UL
listed product.

2.

Pet immunity is not evaluated by UL/ULC.

A. IR LEDs

B. Indication LED 

C. Camera

D. External power LED

E. Alarm LED

Figure 1. External View

2. INSTALLATION

2.1. Installation

A.

Bracket installation (see

Figure 2

). Fix the bracket firmly on a stable wall or pillar. The orientation of the fixed bracket must be as parallel as possible

to the surveyed ground surface.

B.

Adjust the detector's horizontal and vertical angles (see

Figure 3

), according to the surveyed ground surface. Set the vertical angle position

depending on the mounting height and coverage distance that you require. See Figure 3 A and Table 1 for details. The information refers to a
relatively flat surveyed area. Verify the correct installation by using the walk test method.

C.

Fasten the detector to the bracket (see Figure 2 step 4).

Table 1 - Vertical Adjustment Reference

Mounting Height

Coverage Distance

2m / 6.7ft

4m / 13ft

6m / 20ft

8m / 26ft

10m / 33 ft

12m / 39 ft

3.0m / 10 ft

-

1

2

2

3

3

2.5m / 8 ft

1

1

2

3

4

4

2.0m / 7 ft

1

2

3

4

5

5

1.5m / 5 ft

2

3

4

5

5

-

TOWER CAM PG2

PowerG, Outdoor Mirror PIR Motion Detector with Anti-
masking and Built-In Camera

Installation Instructions

Summary of Contents for TOWER CAM PG2

Page 1: ...as can be enrolled l Images multiplexed from all enrolled cameras l Color and black white images l Auto setup l Camera tuning by simple walk test l Day and night CMOS camera with near IR illumination...

Page 2: ...ions only and the distance ranges between 11 to 12 m 36 39ft set the PIR sensitivity to One region Event counter One region Correct Installation Incorrect Installation A Mark drilling point B Screw ho...

Page 3: ...the intrusion detection unit is not to be connected to an alarm initiating circuit but may be connected to a trouble alarm circuit if nuisance trips are not tolerable COVER CLOSURE 1 Release locking...

Page 4: ...er s instructions Caution The battery used in this device may present a risk of fire or chemical burn if mistreated Do not disassemble heat above 66 C or incinerate Replace battery with CR17450 Lithiu...

Page 5: ...n Optional settings ON default and OFF PIR SENSITIVITY Define if the detector operates at regular or high PIR sensitivity or that at least one detection zone must be crossed before an alarm is trigger...

Page 6: ...oor signal from the detector re locate it and re test until a Good or Strong signal strength is received Note For detailed Diagnostics Test instructions refer to the control panel Installer s Guide Th...

Page 7: ...d on the user is encouraged to eliminate the interference by one or more of the following measures l Re orient or re locate the receiving antenna l Increase the distance between the device and the rec...

Page 8: ...NSEQUENTI AL OR PUNITIVE DAMAGES OR FOR LOSS DAMAGE OR EXPENSE IN CLUDING LOSS OF U SE PROFITS R EVEN UE OR GOOD WILL D I REC TLY OR I ND I REC TLY A R ISI NG FR OM PURC HASER S USE OR IN ABI LITY TO...

Reviews: