USER SETTINGS
24
DE5467U
Bypassing Zones
(Not to be used in UL- listed systems)
A. General Guidance
You can program the P to exclude
(bypass) selected zones, regardless of whether
these zones are "functional" (undisturbed) or "open"
(disturbed). Bypassing permits free movement of
people within certain zones although the system is
armed. It is also used to temporarily remove from
service faulty zones that require repair work. Fire
zones can not be bypassed.
Remember – zone bypassing compromises security!
Zone bypassing must be carried out while the system
is in the disarmed state.
Note:
Zones will be bypassed throughout one
disarm-arm period only. Disarming the system after
arming will suspend the entire bypassing scheme,
which can be recalled later, if so desired.
B. Bypassing Procedure
Having entered your user code successfully (see
above - Entering to the User Settings Menue), the
display will read:
SET BYPASS
If at this point you click <
SHOW/OK
>, the number,
state and name of the first zone will be automatically
displayed. Three states are possible:
•
Open:
The zone is not secured - you can
bypass it if you do not wish or know how to solve
the problem just now.
•
Bypassed:
The zone is presently bypassed
(you bypassed it before but haven't armed the
system yet).
•
Functional:
If there is nothing wrong with the
zone, its state is described as "Functional".
Let us assume that Zone 1 is "open" and you wish to
bypass it, and the rest of the zones are functional.
PRESS RESULTANT
DISPLAY
Z01: OPEN
(alternating)
KITCHEN
<OK> TO BYPASS
Z01: BYPASSED
(alternating)
KITCHEN
Z02: FUNCTIONAL
(alternating)
FRONT DOOR
(If you wish
to check the
state of the
next zone)
SET BYPASS
You can select any other item on the USER SETTINGS
menu or quit programming by clicking <
AWAY
>. When
<
OK
>
TO EXIT
is displayed - click <
OK
>.
After end of bypassing operation,
BYPASS
blinks:
READY BYPASS
or NOT READY BYPASS
This indication will persist as long as the system
remains disarmed, and will disappear once the
system is armed.
Note: BYPASS
will alternate in the display with other
messages, like:
Trouble
,
Memory
and
Message
.
C. "Unbypass" Procedure
Suppose you wish to restore a zone to service after
having completed the bypassing scheme. Simply re-
enter the SET BYPASS menu (see Bypassing
Procedure above), and click <NEXT> or <BACK>
until the zone you wish to "unbypass" is on display.
Refer to the following steps.
PRESS RESULTANT
DISPLAY
Z22: BYPASSED
(alternating)
LIVING
ROOM
<OFF> TO CLEAR
Z22: FUNCTIONAL
(alternating)
LIVING ROOM
You may now click <
HOME
> and then select any
other item on the USER SETTINGS menu, or click
<
AWAY
> to quit programming. When <
OK
>
TO
EXIT
appears - click <
OK
>.
Reviewing the Bypassed Zone List
Having entered your user code successfully (see
above - Entering to the User Settings Menu), the
display will read:
SET BYPASS
Click <
NEXT
> to change the display into:
SHOW BYPASS
Click <
SHOW/OK
> to change the display into:
BYPASS LIST
If at this point you click <
SHOW/OK
>, the number,
state and name of the first
bypassed
zone will be
displayed.
You can now click <
NEXT
> repeatedly to review all
bypassed zones, in ascending numerical order. When
done, clicking <
HOME
> will get you back to
SHOW
BYPASS
and clicking <
AWAY
> will get you back to
<
OK
>
TO EXIT.