SECURING THE PROTECTED SITE
DE5467U
11
PRESS RESULTANT
DISPLAY
CODE
_ _ _
CODE
NOT READY HH:MM
(alternating)
NOT READY MEMORY
ARM
indicator extinguishes
To read the alarm memory, refer to Chapter 5.
The "
MEMORY
"
message
will disappear only
when you rearm the system.
If you do not know how to return the disturbed
zone to normal, consult your installer.
D.
Disarming with the system in a state of
trouble:
If trouble is detected in the armed state,
the TROUBLE indicator on the front panel will
light and the disarming operation will progress as
shown:
PRESS RESULTANT
DISPLAY
CODE
_ _ _
CODE
READY HH:MM
(alternating)
READY TRBL
ARM
extinguishes and
sounds once
per minute,
To find out what kind of trouble is being sensed,
see Chapter 5. The
TRBL
display will disappear,
the
TROUBLE
indicator will extinguish and the
trouble beeps will stop upon eliminating the cause
for trouble.
E.
Disarming after an alarm, with the system in a
state of trouble:
The
TROUBLE
indicator on the
front panel will light. If the zone that alarmed while
the system was in the armed state is back to
normal, the disarming operation will progress as
shown:
PRESS RESULTANT
DISPLAY
CODE
_ _ _
CODE
READY HH:MM
(alternating)
READY TRBL
(alternating)
READY MEMORY
ARM
extinguishes and
sounds once
per minute.
To find out which zone alarmed and what kind of
trouble is being sensed, see Chapter 5. The
TRBL
display will disappear, the
TROUBLE
indicator will extinguish and the trouble beeps will
stop upon eliminating the cause for trouble. The
MEMORY
message will disappear only upon
rearming the system.
F. Disarming under Duress
. If you are forcibly
compelled to disarm the system, enter the default
duress code (
2580
)
or another code set by the
installer. Disarming will take place normally but a
silent alarm will be transmitted to the central
station.
Siren Behavior
Continuously ON
when initiated by a burglar zone
or a 24-hour zone, and when a user initiates a “panic
alarm”.
When initiated by a fire zone (smoke is detected)
ON -
ON - ON - pause - ON - ON - ON - pause - ........
and so on.
If there is nobody around to disarm the system upon
alarm and a zone remains "open", the siren will
sound for the time duration set by the installer - then
will stop. The strobe light keeps flashing until the
system is disarmed.