APPENDIX A. Specifications
A1. Functional
Zones Number
Up to 64 wireless zones. The EXP-33 Expander Module includes 8 hard-wired inputs and
the Expander Module includes 2 hard-wired inputs.
Hard-wired Zone
Requirements
2.2 k
Ω
E.O.L. resistance (max. resistance of wires 220
Ω).
Maximum Loop Current
1.5 mA
Maximum Loop Voltage
3.3 V
Shorted Loop Voltage
0 – 1.38 V (0 – 1.76
Ω)
Normal Loop Voltage
1.38 – 1.69 V (1.77 k
Ω – 2.64 k Ω)
Open Loop Voltage
2.18 – 3.3 V (5.26 k
Ω - ∞ Ω)
Installer and User Codes
•
1 master installer (9999 by default)*
•
1 installer (8888 by default)*
•
1 master user, no. 1 (1111 by default)
•
Users nos. 2 - 48
* Codes must not be identical
Control Facilities
-
Integral keypad, wireless keyfobs and keypads
-
SMS commands via optional cellular module.
- Remote control by telephone.
Arming Modes
AWAY, HOME, AWAY-INSTANT, HOME-INSTANT, LATCHKEY, FORCED, BYPASS.
Alarm Types
Silent, personal panic/emergency, burglary, gas, fire and flood.
Siren Signals
Continuous (intrusion / 24 hours / panic); triple pulse – short pause - triple pulse... (fire);
four pulses – long pause – four pulses... (gas);
long pulse – long pause – long pulse... (flood).
Siren (bell) Timeout
Programmable (4 min. by default)
Internal Sounder Output
At least 85 dBA at 10 ft (3 m)
Supervision
Programmable time frame for inactivity alert
Special Functions
- Chime zones
- Diagnostic test and event log.
- Local and Remote Programming over Telephone, cellular connections.
- Calling for help by using an emergency transmitter.
- Tracking inactivity of elderly, physically handicapped and infirm people.
- Message center (recording and playback)
Data Retrieval
Alarm memory, trouble, event log
Real Time Clock (RTC)
The control panel keeps and displays (by KP-250) time and date. This feature is also used for the
log file by providing the date and time of each event
Battery Test
Once every 10 seconds
Note:
The PowerMaster-33 system allows you to authorize up to 48 people to arm and disarm the system by providing each with a
unique 4 digit personal security code (code 0000 is not allowed, maximum number of variations of PIN codes for each user -
10000 for logical keys), and assigning them with different security levels and functionalities. For more information, refer to
Chapter 6, section B.4 of the KP-250 PG2 manual.
For details on programmable functions provided, information about number of invalid code entries before user interface is
disabled, refer to Chapter 6, section A1, A2 of the KP-250 PG2 manual.
Up to 1000 events are stored in the event log that can be reviewed via the Remote Programmer PC software application or
by the remote PowerManage server. For further information about event log capacity, refer to Chapter 9, Maintenance of the
KP-250 PG2.