EXTERNAL POWER CONNECTION
Connect the power adaptor to the front panel power connector.
Figure 3.9b – External Power Connection
3.9.1 Battery Insertion
Open battery compartment cover.
Insert one 6-battery pack or 8-battery
pack and connect its connector as
shown in Figure 3.8c.
A
. Front panel
B.
Battery cable
C.
Battery cable connector
D.
Slot for battery cable
Figure 3.9c – Battery Insertion
3.9.2 Connect AC Power to the Unit
Connect power to the PowerMaster-33 G2 to mains power outlet (see Figures 3.9a and 3.9b).
Disregard any “trouble” indications pertaining to lack of battery or lack of telephone line connection.
For Europe Safety Compliance:
a. The model shall be installed according to the local electrical code.
b. The circuit breaker shall be readily accessible.
c. The rating of the external circuit breaker shall be 16A or less.
D-306917
PowerMaster-33 G2 Installer's Guide
19