background image

D-300058 

NEXT PLUS MCW, NEXT PLUS K9-85 MCW 

 

 

English 

Wireless, PowerCode Digital PIR / Pet Immmune PIR 
Detectors - Installation Instructions 

 

 

Español 

Detectores PIR Digital / Inmune a mascotas inalámbricos – 
Instrucciones de instalación 

 

 

Portuguese 

Detector PIR Digital / Imune a Animais Via rádio – Instruções 
de Instalação 

GB/US: 

Walk-Test LED

SP:

 LED de modo de pruebas

PT: 

LED do teste de passagem

GB/US: 

Lens

SP:

 Lente

PT:

 Lente

 

Fig. 1 - NEXT PLUS MCW / NEXT PLUS K9-85 MCW

 

  

ENGLISH 

1. INTRODUCTION 

The 

NEXT PLUS MCW

 and 

NEXT PLUS K9-85 MCW

 (pet immune) 

are microprocessor-controlled wireless digital PIR detectors.  
NEXT is a registered mark of Visonic Ltd. 

The detectors features are as follows: 

  Combined Fresnel and cylindrical optics improves detection range, 

up to 15 meters (40 ft),  and false alarm immunity. 

  NEXT PLUS MCW includes wall creep zone protection. 

 In 

NEXT PLUS K9-85 MCW

, Target Specific Imaging™ (TSI)

 

technology is used for distinction between human beings and pets 

weighing up to 38 kg (85lb). 

  Incorporates a fully supervised PowerCode transmitter. 

 The advanced 

True Motion Recognition™ 

algorithm (patented) 

allows distinguishing between the true motion of an intruder and any 

other disturbances which may cause false alarms. 

  Sophisticated frequency domain digital signal processing. 

  No vertical adjustment is needed. 

 An on-board motion event jumper determines whether 1 or 2 

consecutive motion events trigger an alarm. 

  Automatic termination of walk-test after 15 minutes. 

  After detection, the detector disarms itself to save battery power. It 

rearms (reverts to the ready state) if there is no subsequent 

detection throughout the following 2-minute period. 

 An optional version provides better protection for systems 

compliant with DD243. After initial detection, the detector is 

capable of 7 additional detections for a period of 5 minutes.  

Further detection is possible only if no movement occurs during the 

following 2 minutes. The detector will revert to the initial state if 

there is no movement for an additional 5 minutes. 

  Microprocessor-controlled temperature compensation. 

  Sealed chamber protects the optical system. 

  Front cover tamper switch. Option - Back tamper switch. 

  White light protection. 

For UL installations:

 The detector is for use with UL listed control 

unit P only. Pet immunity has not been evaluated by UL. 

2. SPECIFICATIONS 

Detector Type: 

Dual element low-noise pyroelectric sensor.

 

Lens Data

 

  No. of Curtain Beams / curtains:

  

NEXT PLUS MCW: 18 far, 18 mid, 10 close.  

NEXT PLUS K9-85 MCW: 18 far, 18 mid, 18 close. 

 Max. 

Coverage: 

15 x 15 m,   (49 x 49 ft) / 90° 

Pet Immunity (NEXT PLUS K9-85 MCW Only):

 Up to 38 kg (85 lb). 

ELECTRICAL 

Internal Battery:

 3V Lithium battery, type CR-123A. For UL installations, use 

Panasonic or Sanyo only. 

Nominal Battery Capacity:

 1450 mA/h. 

Standby Current Drain: 

Approx. 0.025 mA. 

Transmit Current Drain: 

20 mA (including LED). 

Battery Life (with LED on): 

Typically over 3 years. 

Battery Power Test: 

Performed immediately upon battery insertion 

and periodically after every several hours.

 

FUNCTIONAL 

True Motion Event Verification:

 2 position selector - 1 (OFF) or 2 

(ON) motion events. 

Alarm Period:

 3 seconds. 

Visual Indications:  

LED Lights 

for about 3 seconds upon transmission of alarm & 

tamper messages and upon motion detection in the walk test mode.  

LED Flashes

 during the power-up stabilization period, or after 

restoring (pressing) the tamper switch. 

LED Does not light 

upon transmission of supervision messages.  

Rearm Timer:

 Rearms the detector 2 minutes after the last alarm. 

Timer disabled in the walk test mode – not applicable for the DD243 

version (see section 1). 

WIRELESS 

Frequency (MHz): 

315 (U.S. version), 433.92, 868.95, 869.2625 or 

other frequency according to local requirements. 

Transmission Sequence:

 3 data bursts at variable intervals within 3 sec.

 

Encoding: 

 24-bit ID, over 16 million possible combinations. 

Total Message Length:

 36 bits. 

Tamper Alert:

 Reported when a tamper event occurs and in any 

subsequent message, until the tamper switch is restored. 

Supervision Message: 

Signaling at 60 minutes interval (U.S. version), 

15 minute interval (UK version) or according to local standards. 

MOUNTING

  

Height:

 1.8 - 2.4 m (6 - 8 ft). For NEXT PLUS K9-85 MCW, the 

recommended height is up to 2.1 m (7 ft) 

Installation Options:

 Surface or corner. 

ACCESSORIES:  

BR-1:

 Surface mounted swivel bracket, adjustable 30° down and 45° 

left/45° right.  

BR-2:

 BR-1 with a corner adapter  

BR-3:

 BR-1 with a ceiling adapter 

ENVIRONMENTAL

 

RFI Protection: 

>20 V/m up to 2000 MHz. 

Operating Temperatures:

 -10°C to 50°C (14°F to 122°F). 

Storage Temperatures:

 -20°C to 60°C (-4°F to 140°F). 

Compliance with Standards:

 Designed to meet FCC Part 15 and Directive 

1999/5/EC of the European Parliament. En 50131-1 Grade 2 (detector with back 

tamper switch) / Grade 1 (detector without back tamper switch), Class II.

 

PHYSICAL 

Size (H x W x D):

 94.5 x 63.5 x 53.0 mm (3-11/16 x 2-1/2 x  2-1/16”). 

Weight (with battery):

 70 g (2.5 oz). 

Color:

 White. 

PATENTS: 

U.S. Patents 5,693,943 

z

 6,211,522 

z

 D445,709 (another 

patent pending). 

3. INSTALLATION 

3.1 General Guidance

 

(see fig. 3) 

1. Keep away from heat 

sources. 

2. Do not expose to air drafts. 

3. Do not install outdoors. 

4. Avoid direct sunshine. 

5. Keep wiring away from power 

cables. 

6. Do not install behind partitions. 

7. Mount on solid stable surface. 

 

 

Important! The K9-85 detector is immune to 38 kg (85 lb) 

animals moving on the floor or climbing on furniture as long as 

the activity takes place below 1 m (3 ft). Above the 1 m (3 ft) 

height limit, the detector is immune to 19 kg (42 lb) pets, but 

the pet immunity will decrease as the pet gets closer to the 

detector. It is therefore recommended to select a mounting 

location that minimizes potential close proximity of animals.

 

  

3.2 Installation Procedure 

1. Mounting - see fig. 4. 

2. Battery installation (see fig. 4 and the note below) 

3. Detector reset: 

With the battery in place, press both tamper switches 

simultaneously (see fig. 4) and release them. The front LED will 

flash for about 2 minutes until the detector stabilizes.  

Note: The detector transmits a low battery signal upon detection of 

low voltage. It is recommended to wait about 1 minute after battery 

removal, before inserting the new battery. 

4. Enrolling: 

Enroll the detector's ID into the alarm system memory according to 

the alarm system insallation instructions. When you are instructed 

to transmit, press both tamper switches again and release them. 

You may enroll the detector's ID while the detector's LED flashes. 

5. Jumpers settings - see fig. 5. 

6. Walk-test the coverage area - see fig. 2 and the note below. Walk 

across the far end of coverage pattern in both directions. The LED 

should light for 2-3 seconds each time your motion is detected. 

Important!

 Instruct the user to walk test at least once a week to 

verify proper function of the detector. 

Note: Upon battery insertion or closing the cover (which results in 

closing the tamper switch) the LED flashes for 2 min  and the detector 

goes into walk-test mode for 15 min. In walk-test mode, regardless of 

the LED jumper position, the LED lights upon every motion detection. 

After 15 minutes the detector automatically enters normal mode in which 

the LED functions according to the LED control jumper position. 

Reviews: