Barcode reader VB34
Technical data
Da
te
of
issue
06/
1
3
/2005
93
Subject to reasonable modifications due to technical advances.
Copyright Fuchs, Printed in Germany
Fuchs Group • Tel.: G49 621 776-0 • USA +1 330 4253555 • Sin65 67799091 • Internet http://www.pepperl-fuchs.com
11
Technical data
Remark 1:
If not otherwise indicated, all specifications refer to an ambient temperature
of 25 °C.
Electrical features (see remark 1)
Operating voltage
Power consumption
15 to 30 V DC
15 W typically
20 W max. (including starting current)
Communication interfaces
Primary (galv. sepa-
rate)
Baud rate
RS232
RS485 full-duplex
RS485 half duplex
20 mA current loop
(with INT-60 accesso-
ries)
1200 to 115200
1200 to 115200
1200 to 115200
19200
Secondary
RS232
1200 to 115200
Miscellaneous
Lonworks
Ethernet
DeviceNet
Profibus
1,25 Mb/s
10 or 100 Mb/s
125 or 250 Kb/s
12 Mb/s
Inputs
(NPN or PNP, with optocouplers
External trigger 1
3 additional digital inputs
Outputs (with optocouplers)
3 digit outputs programmable by software
Figure system (see remark 1)
Light receiver
Wave length
Safety class
Laser control
APD (avalanche photodiode)
630 to 680 nm
Class 2 - EN60825-1; Class II - CDRH
Safety system switches off laser when motor
becomes slower
Optical properties:
Scan rate
Maximum resolution
Max. reading distance
Max. reading width
Max. depth of the field
Deflection angle
600-1200 read processes/sec
(see reading fields)
(see reading fields)
(see reading fields)
(see reading fields)
(see reading fields)
Operator interface
LCD display
Key field
Status LEDs
2 lines each with 16 characters
3 keys
Power ON (red)
Phase ON (yellow)
TX Data (green)