Result – the response indicates that the command was not valid (the command sent
should have been GT200 as in the example above). The unit will not action this
command.
Error 2 – invalid parameters
Responds with current settings
Example
Command to set the transmit gain to -50.0dB.
The command is ‘GT’ and the valid range for the parameters is 000 to 400.
Command sent
GT500
Response from unit
GT200
Result – the response indicates that the parameters were not valid (-50.0dB is outside
the range for this unit). Response indicates that the current value is –20.0dB i.e. no
changes have been made.