Visive Hi-Lite 30 Border Installation Manual Download Page 1

Installation guide

v6 June 2021

Summary of Contents for Hi-Lite 30 Border

Page 1: ...Installation guide v6 June 2021 ...

Page 2: ...n this guide Failure to install Hi Lite 30 as described in this document will void any product warranty If you have any queries regarding the content of this guide please call 44 0 1978 660181 or email technical visivegroup com Hi Lite 30 LED contour tube specification installation v6 June 2021 ...

Page 3: ...nnect the Hi Lite 30 sections to the power supply 3 and are also used to bridge gaps around other signage or building features When the electrical connection must continue after an adjustable section for example around a corner a Y connection splitter 5 is used together with a connection cable Blanking plugs 6 must be fitted to any unused connectors at the end of tube runs Installation key 1 Standa...

Page 4: ...ve a connector at one end only and once cut to length the remaining portion is discarded The Hi Lite 30 system also includes a range of IP rated power supply units as well as connection cables Y adapters clips and connector blanking plugs Polycarbonate mounting clip Y splitter adapters Connector blanking plugs supplied with power supplies SCIGRIP 16 acrylic cement adhesive for applying Field Adjus...

Page 5: ...tion clip should be used in the centre of the section This clip features a rubber O ring to increase the grip on the tube thereby locking it in position Only one high friction clip must be used per section 400mm 1 3 400mm 1 3 400mm 1 3 400mm 1 3 400mm 1 3 400mm 1 3 50 70mm 2 2 50 70mm 2 2 This way up Chalk centre line Fixing screw rivet Head diameter min 7mm 0 3 max 9mm 0 35 Standard clip 4 On ver...

Page 6: ...sure the tube is properly located in the clip and that no wires are trapped A click should be heard when the tube is located correctly 8 Hi Lite 30 tube section clipped in place with the cable positioned ready to connect to the next section 9 Connect the next tube looping the cable around in the rear channel Once again leave a loop of cable to allow for thermal movement 10 In order to maintain wea...

Page 7: ...mple The Y adapter can be hidden behind the tube in the same way as a standard connection 15 If a connection cable needs to be shortened this can be done using two 3M Scotchlok gel filled pigtail connectors such as type UY2 The completed connection can be hidden in the tube channel as shown 3M 3M 3M Connection cable 3M Scotchlok UY2 pigtail connectors 12 DO NOT butt sections up together Doing so wi...

Page 8: ...t dots along the rear of the tube Mark the required cut position 2 Field Adjustable sections must be cut from the connector end only The portion cut off without a connector is scrap and cannot be used Cut through the Hi Lite 30 section at your mark using a hacksaw fitted with a fine toothed blade Use a mitre box to ensure a clean square cut 3 Remove any burrs and foreign material from the cut end En...

Page 9: ...tically performs tests on the DC supply to the Hi Lite installation Should a fault be detected the DC output is switched off Once this has occurred a series of attempts to reinstate the DC supply are made at intervals increasing from 1 second to 1 hour Should any re try be successful the DC output is switched on and the CSC enters a back off mode Whilst in this back off mode the re try period that...

Page 10: ...ed out at 10 second intervals during normal operation 6 pulses Run time voltage test failure This test is carried out at 10 second intervals during normal operation and a failure indicates either a faulty or damaged tube section usually with water ingress or the connectors contain trapped water 7 pulses Start up voltage test failure Similar to 6 pulses but this test is carried out at start up befo...

Page 11: ...ower supply outputs are not used be sure to fit a blanking plug to the unused connector Power supply Total output power Hi Lite 30 green HL3 xx G5 All other colour codes 18m 59 1 total in any configuration across the two outputs 36m 118 3 total in any configuration across the two outputs 43m 141 1 max on each output 86m 282 2 total N A 4m 13 1 total in any configuration across the two outputs 19m 62 4...

Page 12: ...or Email za auxisolution com Ireland Distributor Trimwel Ltd 2A Canal Bank Hume Avenue Park West Industrial Estate Dublin 12 Ireland T 00 353 0 12940188 Email info trimwel ie Distributor Bever Innovations B V Industrieweg 32 4301 RS Zierikzee The Netherlands T 31 0 111 453 232 Email info beverinnovations com Distributor dk LED Ekkersrijt 1209 5692 AG Son en Breugel The Netherlands T 31 499 476 777...