Vision ZM1601 Quick Start Download Page 5

Battery Type

4 * AA

Explorer Frame Support Yes

SDK

4.54.01

Device Type

Slave with routing capabilities

Generic Device Class

Binary Switch

Specific Device Class

Specific Device Class not used

Routing

No

FLiRS

No

Firmware Version

1.65

Explanation of Z-Wave specific terms

Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically 

Gateways, Remote Controls or battery operated wall controllers.

Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators 

and even remote controls.

Primary Controller — is the central organizer of the network. It must be a controller. There can be only one 

primary controller in a Z-Wave network.

Inclusion — is the process of bringing new Z-Wave devices into a network.

Exclusion — is the process of removing Z-Wave devices from the network.

Association — is a control relationship between a controlling device and a controlled device.

Wakeup Notification — is a special wireless message issued by a Z-Wave device to annonces that is is 

able to communicate.

Node Information Frame — is a special wireless message issued by a Z_Wave device to announce its 

capabilities and functions.

Disposal Guidelines

The product contains batteries. Please remove the batteries when the device is not used.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. 

Contact your local government for information regarding the collection systems available. If electrical 

appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and 

get into the food chain, damaging your health and well-being.

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 5 

Summary of Contents for ZM1601

Page 1: ...an act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated...

Page 2: ...lding will know immediately that an alarm has occurred The device can be configured to either use the strobe flash or the acoustic siren or both A tamper switch protects the device from removal or manipulation if used in security applications The device is battery powered by 4 AA standard batteries Batteries The unit is operated by batteries Use only batteries of correct type Never mix old and new...

Page 3: ...conds ZM1601 will enter Self Protection Mode If the back cover is opened will trigger the Self Protection Mode The alarm time is default 30 seconds User s controller should support Z wave FLiRS technology Alarm Mode It is the status of alarm triggered It is based on the user s configuration setting of LED flash ON OFF and Siren ON OFF Note for Default setting Siren Strobe Mode Parameter will be Al...

Page 4: ...umber 0 Parameter Size 1 defines the reaction of the siren Value Description 0 Strobe and Siren Default 1 Siren only 2 Strobe only Alarm auto stop Parameter Number 1 Parameter Size 1 defines the auto time out of the alarm indication Value Description 1 60 seconds 2 120 seconds 3 no automated off 0 30 seconds Default Command Classes Supported Command Classes Battery version 1 Basic version 1 Binary...

Page 5: ...e process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guide...

Reviews: