Vision ZM1601 Quick Start Download Page 2

5. Actuators control other actuators
6. Remote controls send signals to static controllers to trigger scenes or other actions
7. Remote controls control other actuators.

There are two different role a controller can have. There is always one single primary controller that is managing the 

network and including/excluding devices. The controller may have other functions - like control buttons - as well. All other 

controllers don't manage the network itself but can control other devices. They are called secondary controllers. The 

image also shows that its not possible to operate a sensor just from a remote control. Sensors only communicate with 

static controllers.

Product description

The siren will warn everybody in the building by a loud sound and a flashing light about an alarm. This 

product is especially suited for security applications in combination with other Z-Wave devices such as door 

or windows sensors or motion detectors. The siren gives a loud sound and a flashing warning light, so that 

everybody in the building will know immediately that an alarm has occurred. The device can be configured to 

either use the strobe flash or the acoustic siren or both. A tamper switch protects the device from removal or 

manipulation if used in security applications. The device is battery powered by 4 AA standard batteries.

Batteries

The unit is operated by batteries. Use only batteries of correct type. Never mix old and new batteries in the 

same device. Used batteries contain hazardous substances and should not be disposed of with household 

waste!

Battery Type:  4 * AA

Installation Guidelines

1. Remove the bracket from the siren by pressing the locking tab and then gently slide up the siren. 

Observe the correct polarity before insert the batteries.

2. Using the screws or adhesive tape to affix the bracket on the chosen location.
3. Slide back the cover and screw fastening with the front cover, the LED should go off.

Please note: 

LED setting light will flash continuously in Exclusion condition.

ZM1602 can only connect to DC 12~39V, AC 9~28V Power adapter.

ZM1602 is extremely LOUD, please do not near your ear when you test!

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 2 

Summary of Contents for ZM1601

Page 1: ...an act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated...

Page 2: ...lding will know immediately that an alarm has occurred The device can be configured to either use the strobe flash or the acoustic siren or both A tamper switch protects the device from removal or manipulation if used in security applications The device is battery powered by 4 AA standard batteries Batteries The unit is operated by batteries Use only batteries of correct type Never mix old and new...

Page 3: ...conds ZM1601 will enter Self Protection Mode If the back cover is opened will trigger the Self Protection Mode The alarm time is default 30 seconds User s controller should support Z wave FLiRS technology Alarm Mode It is the status of alarm triggered It is based on the user s configuration setting of LED flash ON OFF and Siren ON OFF Note for Default setting Siren Strobe Mode Parameter will be Al...

Page 4: ...umber 0 Parameter Size 1 defines the reaction of the siren Value Description 0 Strobe and Siren Default 1 Siren only 2 Strobe only Alarm auto stop Parameter Number 1 Parameter Size 1 defines the auto time out of the alarm indication Value Description 1 60 seconds 2 120 seconds 3 no automated off 0 30 seconds Default Command Classes Supported Command Classes Battery version 1 Basic version 1 Binary...

Page 5: ...e process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guide...

Reviews: