IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128 

… 255 the value sent in the application shall be the desired value minus 256. For example: to set a 

parameter to 200? it may be needed to set a value of 200 minus 256 = minus 56. In case of two byte value 

the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Siren Strobe Mode (Parameter Number 0, Parameter Size 1) defines the reaction of the siren

Value

Description

0

Strobe and Siren (Default)

1

Siren only

2

Strobe only

Alarm auto stop (Parameter Number 1, Parameter Size 1) defines the auto time out of the alarm indication

Value

Description

1

60 seconds

2

120 seconds

3

no automated off

0

30 seconds (Default)

Command Classes

Supported Command Classes

Battery (version 1)

Basic (version 1)

Binary Switch (version 1)

Version (version 1)

Configuration (version 1)

Manufacturer Specific (version 1)

Technical Data

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 4 

Summary of Contents for ZM1601

Page 1: ...an act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated...

Page 2: ...lding will know immediately that an alarm has occurred The device can be configured to either use the strobe flash or the acoustic siren or both A tamper switch protects the device from removal or manipulation if used in security applications The device is battery powered by 4 AA standard batteries Batteries The unit is operated by batteries Use only batteries of correct type Never mix old and new...

Page 3: ...conds ZM1601 will enter Self Protection Mode If the back cover is opened will trigger the Self Protection Mode The alarm time is default 30 seconds User s controller should support Z wave FLiRS technology Alarm Mode It is the status of alarm triggered It is based on the user s configuration setting of LED flash ON OFF and Siren ON OFF Note for Default setting Siren Strobe Mode Parameter will be Al...

Page 4: ...umber 0 Parameter Size 1 defines the reaction of the siren Value Description 0 Strobe and Siren Default 1 Siren only 2 Strobe only Alarm auto stop Parameter Number 1 Parameter Size 1 defines the auto time out of the alarm indication Value Description 1 60 seconds 2 120 seconds 3 no automated off 0 30 seconds Default Command Classes Supported Command Classes Battery version 1 Basic version 1 Binary...

Page 5: ...e process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guide...

Reviews: