Page.14
No ACTION
Possible problem/cause
Solution
1.
Option: wall switch START:
press ON button > wall switch
works.
NO
Bent pin on switch, or cable
not operating properly.
Straighten pin, replace wall
switch or cable.
1.
Manual transmitter START:
press both buttons to start
ignition sequence.
Beep will occur each second
NO
Manual transmitter battery
low.
Replace battery, 2x AAA 1.5V
quality alkaline!
Receiver batteries low.
Replace batteries, 2x AA 1.5V
quality alkaline!
Optional mains adapter not
operating properly.
Check mains adapter.
Check coding of transmitter
and receiver.
Learn in new code, see
instructions and label on
receiver.
OK
Transmitter/receiver range
limited.
1.
Move antenna cable,
see instructions.
2.
Replace receiver.
Optional wall switch / cabling
not operating properly.
Replace wall switch / cabling.
Receiver fuse blown (in older
versions only).
Replace receiver.
2.
Magnet unit in gas valve is
energised (audible click)
NO
No beep
Impulse magnet not
operating properly.
Replace gas valve.
NO
3 short
beeps
Receiver batteries low.
Replace batteries, 4x 1.5V AA
quality alkaline!
NO
1 long beep ON/OFF switch on gas valve
in OFF position
Set switch to ON.
8-wire cable between receiver
and gas valve defective /
poor contact.
Check cable, especially in case
of plug connection.
OK
Switch cable disconnected.
Check switch cable, see fig. 1
on page 18
Motor not operating properly. Replace gas valve.
Micro switch on gas valve not
operating properly.
Replace gas valve.
11. TROUBLESHOOTING LIST MERTIK GV60
Summary of Contents for 1053
Page 1: ...INSTALLATION INSTRUCTIONS FOR MODELS TL38 TL38C TL38P ...
Page 62: ...Page 12 9 KORREKT PLACERING AF TERMINALER OG FUNKTION ...
Page 99: ...Pag 1 1053 1054 1055 APPENDIX 1 DIMENSIONAL DRAWINGS HOEK LINKS RECHTS PANORAMA ...
Page 100: ...Pag 2 1070 1071 1072 1073 PANORAMA FRONT HOEK RECHTS ...
Page 101: ...Pag 3 APPENDIX 2 INSTALLATION EXAMPLES A B C C 3 1 2 3 MAX 1000 ...
Page 102: ...Pag 4 APPENDIX 3 INSTALLATION INSTRUCTIONS REGARDING FLUES ...
Page 105: ...Pag 7 APPENDIX 5 PREPARATION AND INSTALLATION 3 2 1 3 2 1 5 4 6 7 ...
Page 106: ...Pag 8 APPENDIX 6 INSTALLING GASCONTROL GV60 3 5 4 GAS CASSETTE 1 2 GAS VALVE BURNER CONTROL ...
Page 107: ...Pag 9 8 7 6 POSITION PILOT BURNER ...
Page 108: ...Pag 10 1053 1054 1055 BP NG APPENDIX 7 FITTING LOG SET 2 5 7 6 8 4 1 3 9 ...
Page 109: ...Pag 11 ...
Page 110: ...Pag 12 1070 1071 1072 1073 ...
Page 111: ...Pag 13 ...
Page 112: ...Pag 14 ...
Page 113: ...Pag 15 ...
Page 114: ...Pag 16 ...