background image

Page 

11

 / 

15

 

Wiring/Cabling & Connecting  

 

 

 

 

 

 

 

 

 

 

 

 

Port Description 

 

z

 Main 

Cable

 

Port Pin Number (RJ45) 

Connector / Wire Color

Signal 

Black 

RS485 + 

Brown 

RS485 

 

Red 

DC 12V 

Orange 

Ground 

Yellow 

OUT COM (Relay Output Common) 

Green 

OUT 2 (Relay Output 2) 

Blue 

OUT 1 (Relay Output 1) 

Violet 

IN COM (Sensor Input Common) 

Gray 

IN 1 (Sensor Input 1) 

10 

White 

IN 2 (Sensor Input 2) 

 

z

 Audio 

Cable

 

Port Pin Number 

Connector/ Wire Color

Signal 

1 RCA 

(Yellow) 

Audio 

IN 

2  

Audio 

GND 

3 RCA 

(White) 

Audio 

OUT 

 

 

 

 

Summary of Contents for VPD200SM2i

Page 1: ...Page 1 HA VPD2 15 RDW 200SM2i WARE FULL INSTA HD NETW TALLA WORK PT ATION TZ Came Rele N GUI ra eased on 1 Vision DE Version 1st of June n Hitech C n 1 0 0 e 2012 Co Ltd ...

Page 2: ...with limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to ...

Page 3: ... content Hardware Installation Guide 1 Precautions 4 2 Limitation of liability 4 3 Disclaimer of warranty 4 4 Package Contents 5 5 Cable Connection 6 6 Installation 7 13 7 Dimension mm 14 8 Specification 14 VPD200SM2i 15 ...

Page 4: ...Be careful not to be stained by fingerprint z Don t face the camera directly toward sunlight or sunlight reflecting area CCD may go defective at this condition z Please give a special attention to keep the unit from dangerous drop or external shock during the process of transportation or handling z Never try to touch the camera in wet hand It may cause an electric shock z Do not expose the camera ...

Page 5: ...tem combined by the devices of third party 6 Any claim or action for damages brought by any person or organization being photogenic subject due to violation of privacy with the result of that surveillance camera s picture including saved data for some reason becomes public or is used for the purpose other than surveillance 4 Package Contents Note Mount Brackets are optional z Wall Mount Bracket z ...

Page 6: ...picture for further tasks Mounting Screw Hole This hole is for screws that assembles the main body with a bracket IP Reset Switch Reset its network configuration to the factory defaults You will lose all data that had been entered previously To initialize the system to the factory default press the reset button for more than 5 seconds LAN Port Used for the Ethernet connection Audio Port Used for t...

Page 7: ...N 1 2 3 4 5 6 7 8 z ID numbers of camera are set up with binary numbers See the examples shown below Pin 1 2 3 4 5 6 7 8 ID Value 1 2 4 8 16 32 64 128 ex ID 5 on off On off off off off off ex ID 10 off on Off on off off off off z The camera ID range is 1 255 Camera ID must not be 0 z Factory default of Camera ID is 1 z Match the camera ID with Cam ID setting of your DVR or Controller to control th...

Page 8: ...OFF ON OFF PELCO P 4800 bps ON ON OFF PELCO P 9600 bps Otherwise Reserved z If you want to control using DVR or P T controller their protocol must be identical to camera Otherwise you can not control the camera z Adjust the DIP switch after turning off the camera If you changed the camera protocol by changing the DIP switch the change will be effective after you reboot the camera z Factory default...

Page 9: ...and cable s for the system as below Line up the mold lines and assemble main body to mount adaptor and turn it And assemble the main both with the camera mount adaptor with the screws Torx screw M4X18 Please make sure the screws are tightly assembled for waterproof Screw the dome cover to the main body and remove the protection vinyl from the dome cover Notice z Before starting the installation ma...

Page 10: ...ce Hex Lag 14 50 Hook up Drop Prevention Spring on main body to prevent camera from unexpected drop and pull the wire s and cable s for the system as below Line up the mold lines and assemble main body to mount adaptor and turn it And assemble the main both with the camera mount adaptor with the screws Torx screw M4X18 Please make sure the screws are tightly assembled for waterproof Screw the dome...

Page 11: ...wn RS485 3 Red DC 12V 4 Orange Ground 5 Yellow OUT COM Relay Output Common 6 Green OUT 2 Relay Output 2 7 Blue OUT 1 Relay Output 1 8 Violet IN COM Sensor Input Common 9 Gray IN 1 Sensor Input 1 10 White IN 2 Sensor Input 2 z Audio Cable Port Pin Number Connector Wire Color Signal 1 RCA Yellow Audio IN 2 Audio GND 3 RCA White Audio OUT ...

Page 12: ...C coaxial cable Connecting Audio Audio is full duplex It is possible to set the mode as Tx only Rx only or Tx Rx 1 Connect audio input and output ports to audio devices accordingly 2 The Audio signal required is line level so an audio equipment with an amp mixer or other amplifier should be used Connecting Serial Port RS 485 Communication z For PTZ control connect the cable s to your keyboard or D...

Page 13: ...of the decoder system works in pass through mode That is data from at one port is delivered to the other port vice versa Connecting Sensor and Alarm Connect sensor and alarm devices to corresponding terminals accordingly z Sensor Input z Relay Output Maximum allowable electrical load of relay is shown bellow table Drive Power DC Power AC Power Max Load Max DC 24V 1A Max AC 125V 0 5A IN COM IN 1 IN...

Page 14: ...ual Bright Shutter Priority Iris Priority Spot GAIN Control Auto Manual 3 28dB Shutter Control Auto Manual 1 1 1 10 000 sec WhiteBlance Auto Manual Red Blue Gain Adjustable Video Compression H 264 baseline profile Motion JPEG Resolutions Up to 1920 x 1080 Frame rate H 264 Up to 15fps with 1920x1080 MJPEG Up to 30fps with 720p resolution Video streaming Support multi stream with H 264 MJPEG Adjusta...

Page 15: ...tp e mail Notification via email FTP and TCP Video buffer 16MB pre alarm and post alarm Recording Save to Micro SD card with event mode and continuous mode Firmware upgrade Remote upgrade via network API CGI Interface document ActiveX Interface ocx dll document Physical RESET Button 1 x Factory Reset Button Power Source DC 12V 5 0A Power Consumption Max 36W Weight Appr 3 800g Wall 3 200 g Ceiling ...

Reviews: