background image

TZB38-IR850-P-24V

Commissioning

Mount the Deflection Mirror

1.)

2.) 3.)

a

a

a

a

b

1. Loosen the M3 threaded pins (a) of the deflection mirror.
2. Attach the deflection mirror on the lighting. Rotate the mirror (b) to the

desired position.

3. Tighten the M3 thread pins alternately hand-tight in small steps.

20

999.995.409.10-en-1.4

© Vision & Control GmbH 2021

Summary of Contents for TZB38-IR850-P-24V

Page 1: ...NTROL Instructions for Use TZB38 IR850 P 24V Telecentric Lights Luminous colour Infrared 850 nm Instructions for Use TZB38 IR850 P 24V Telecentric Lights Luminous colour Infrared 850 nm 999 995 409 10...

Page 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Page 3: ...der no TZB38 IR850 P 24V 1 33 243 Product Identification Designation Description TZB Telecentric Lights 38 Luminous field diameter in mm IR850 Luminous colour Infrared 850 nm P Power LED 24V 24 V DC o...

Page 4: ...e Views 12 4 2 Notices on the device 13 5 Technical Data 14 5 1 General Parameters 14 5 2 Electrical Parameters 15 5 3 Photometric Parameters 15 5 4 Conditions for Operation Storage and Transport 16 5...

Page 5: ...future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potent...

Page 6: ...ns of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1...

Page 7: ...al and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the maint...

Page 8: ...s of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with medium...

Page 9: ...ice and the connected technical equipment Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual CAUTION Risk of injury due to electric s...

Page 10: ...older Designation Description Order no Lens Holder d45 Holder for telecentric lenses and light ings with 45 mm clamping diameter for vibration free attachment 2 90 139 Polarizing filter Filter adapter...

Page 11: ...ed plug 4A 60V Designation Description Order no Connection cable M8 4pin 2m 1 11 605 Connection cable M8 4pin 5m 1 11 604 Connection cable M8 4pin 10m Connection cable with 4 pin M8 socket and open ca...

Page 12: ...RIPTION 4 1 Device Views 1 2 3 6 5 5 5 4 Image 1 Ger teansicht 1 Casing 2 Light emitting surface 3 Identification plate 4 Note screw in depth 5 Mounting surface with mounting holes 6 Connector M8 4pin...

Page 13: ...g instructions are provided on the device Type plate Type TZB38 XXXX P 24V SN XXXXXXXX 1 2 Image 2 Type plate 1 Device designation 2 Serial number Notice Screw in depth screw in depth max 7mm Image 3...

Page 14: ...ght emitting surface Diameter 39 mm Connector Male connector M8 4 pin Weight 280 g Degree of protection IP 50 Safety class Class III safety extra low voltage SELV Risk group DIN EN 62471 Risk group 0...

Page 15: ...ON OFF Input delay tD 50 s 100 s 150 s 5 3 Photometric Parameters Parameter Min Nom Max Peak wavelength peak 860 nm Centroid Wavelength centroid 850 nm Spectral bandwidth 30 nm Full divergence angle 2...

Page 16: ...rve the specified ambient conditions when transporting and storing the device For accessories connected devices and components observe the specific information in the associated instructions for use A...

Page 17: ...Mittelbergstra e 16 98527 Suhl 1 2 3 4 5 1 2 3 4 5 A A B B C C D D M8 connector TZB38 XXXX P 24V TZB38 XXXX HP 24V light emitting surface 3 9 2 x M4 depth 7 17 4 20 23 50 103 20 75 13 45 Image 5 Tech...

Page 18: ...the tucked in sides on the bottom of the cardboard The film loosens and forms an insertion pocket 3 Remove the device out of the insertion pocket 4 Dispose the packing material 6 2 Mounting the Devic...

Page 19: ...3 Tighten the M5 hexagon nuts alternately hand tight in small steps Mount the Filter adapter slip on adapter 1 2 3 a a a 1 Loosen the M3 threaded pins a of the slip on adapter 2 Attach the slip on ada...

Page 20: ...a a b 1 Loosen the M3 threaded pins a of the deflection mirror 2 Attach the deflection mirror on the lighting Rotate the mirror b to the desired position 3 Tighten the M3 thread pins alternately hand...

Page 21: ...cification see data sheet 6 4 1 Pin assignment Use the M8 connector to connect the device according to the pin assignment Pin assignment 1 2 3 4 Image 7 M8 connector 4 pin Connection diagram V GND 1 3...

Page 22: ...ere there are flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during operation directly in LED lighting or whose rays Wear protective goggles In the event o...

Page 23: ...resetting the switching signal ON OFF Consider the switching delay time td of the lighting Set the exposure time of the camera to be within the tON range The length of the Power on time tON correspond...

Page 24: ...leaning the optical surfaces NOTICE Follow the specified cleaning sequence Never use dry cloths for cleaning This allows dust and other contaminants to be rubbed into the lens surface thereby damaging...

Page 25: ...lad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective device...

Page 26: ...eparately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done...

Page 27: ...al environments DIN EN IEC 61000 6 4 2020 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and meas...

Page 28: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...