119_99
6.3 Digital Inputs and Outputs
Connection to PLC / trigger inputs
Figure 8:
Connection of digital inputs (PLC IN/TriggerIN)
• 2 digital inputs
• 1 trigger input
• Operating voltage 12 - 24 V
• Threshold voltage 8 V (high input for signals of more than 8 V)
• Maximum voltage: 30 V
• Reverse polarity protection
• Input current 2 mA @ 24 V
• Debouncing hardware: none
External Switch, Relais,
PLC, Light Barrier, etc.
12 - 24 V
GND (Black Cable)
Inside Camera