The Vision & Control pictor N Series user manuals can be downloaded for free from our website. Ensure you have the manual to control and optimize your vision system's performance. Get your user manual today at manualshive.com.
the easy way of machine vision
999.994.899.10-en-1.0© Vision & Control GmbH 2017
User Manual
pictor® N
Intelligent camera
Page 1: ...the easy way of machine vision 999 994 899 10 en 1 0 Vision Control GmbH 2017 User Manual pictor N Intelligent camera...
Page 2: ...eserved vicotar vicolux pictor vicosys and vcwin are trademarks of Vision Control GmbH The products and brand names of other manufacturers or suppliers are mentioned for information only Validity Thes...
Page 3: ...LC Power cable 5 m HRS female 12 pin without connector 4 40 223 pictor PLC Power cable 10 m HRS female 12 pin without connector 4 40 224 pictor PLC Power cable 25 m HRS female 12 pin without connector...
Page 4: ...dicator Lights 14 3 8 Dimensional Drawing 15 4 Packaging and Transportation 16 4 1 Storage 16 5 Installation and Mounting 17 5 1 Mounting the Device 17 5 2 Mount Accessories Mounting Lens 18 6 Operati...
Page 5: ...pictor N Table of Contents Vision Control GmbH 2017 5 170119_999 994 899 10 en 1 0 8 4 Accessories 32 9 Disposal 33 10 Declaration of Conformity 34 11 List of Changes 35 12 Notes 35...
Page 6: ...read completely and carefully in order to avoid hazards and the need for repairs and to reduce downtimes and lengthen the service life of the device The instructions must always be present at the ope...
Page 7: ...s introduced by a key word and colour highlighted The key word indicates the degree of danger WARNING Indicates a potentially dangerous situation If this situation is not avoided fatality or very seri...
Page 8: ...instruction and supervision of qualified electricians Never work on device when it is powered up Before starting work on the device disconnect it from the operating voltage Never remove stickers or l...
Page 9: ...imitation of liability The manufacturer shall not be held liable for any damage that occurs as a result of Use for any purpose other than intended Non compliance with this guide Opening the device and...
Page 10: ...Labelling of the Device Product name Designation Quantity Device pictor N 1 x Product DVD with vcwin pro operating software pictor N installation and operating instructions PDF vcwin pro software man...
Page 11: ...0 Rating plate The rating plate contains the following information Figure 1 Plate on the rear side M Monochrom C Colour with Bayer filter ETH Interface Ethernet 1 Manufacturer name 2 Device name 3 Se...
Page 12: ...170119_999 994 899 10 en 1 0 3 5 Views of Unit Figure 2 Device view Front side 1 Ethernet interface 2 PLC Power interface 3 Indicator lights 4 Housing 5 Image recorder window 6 CS mount lens connecto...
Page 13: ...Figure 3 Device view Rear side 3 6 Interfaces and Connections Figure 4 Interfaces and connections 1 2x M6 tapped hole Maximum screw in depth 8 mm 2 1x tapped hole 1 4 Maximum screw in depth 8 mm 3 Ra...
Page 14: ...cific operating states of the intelligent camera Figure 5 Indicator lights LED Colour Status Remark LED indicator lights Out 3 red ON at High Out 2 red ON at High Out 1 red ON at High Out 0 red ON at...
Page 15: ...tor N Product Description Vision Control GmbH 2017 15 170119_999 994 899 10 en 1 0 3 8 Dimensional Drawing Figure 6 Mechanical dimensions all dimensions in mm 0 R X Q W 0 G H S W K 0 G H S W K G H S W...
Page 16: ...y be transported in its original packaging or in other suitable packaging Adapters and mounted parts must be dismounted before the device is transported The packaging materials must be disposed of in...
Page 17: ...vice on the rear side Figure 7 Mounting holes Rear side NOTICE Damage to the device through overheating The device must not be operated if it is covered or in packaging Make sure there is enough clear...
Page 18: ...otective cap from the lens mount For C mount lens screw on the CS C mount adapter included in the scope of delivery hand tight For M12 mount lens screw on the M12 adapter accessories hand tight 3 Scre...
Page 19: ...age to the cable Comply with the specified minimum bending radius Always mount cables with a strain relief clamp NOTICE Destruction to the device by potential differences Ensure that the housing of th...
Page 20: ...5 plug to a free Ethernet interface on the host computer or the network 6 1 1 Pin Assignments Properties Ethernet interface The pictor N is integrated in a LAN and interface for process communication...
Page 21: ...unicating with a host computer or network IP configuration in the as supplied state During the start the device searches for a DHCP server in the LAN If no DHCP server is available in the LAN Ethernet...
Page 22: ...ice 2 Connect the open end of the PLC power cable to the control unit power supply NOTICE The maximum permissible current per connector contact is limited see chapter 8 2 Electrical Parameters on page...
Page 23: ...O supply voltage 2 red blue 12 24 VIN Cam Camera operating voltage 3 black GND GND 1 4 pink IN 1 Digital input 1 5 yellow OUT 3 Digital output 3 6 green OUT 2 Digital output 2 7 brown OUT 1 Digital ou...
Page 24: ...Connection of digital inputs PLC IN TriggerIN 2 digital inputs 1 trigger input Operating voltage 12 24 V Threshold voltage 8 V high input for signals of more than 8 V Maximum voltage 30 V Reverse pol...
Page 25: ...trigger output Operating voltage 12 24 V Current per output 400 mA total current for all output 1000 mA Connect the 12 24 V PCL and the I O supply voltage to the socket contacts 1 2 and 9 The High ou...
Page 26: ...e RAM Monitor with a resolution of at least 800 x 600 pixels Ethernet interface Installation 1 Insert the supplied DVD into the drive of the host computer 2 Select option Open Autorun menu or double c...
Page 27: ...the device There is no automatic update The operating software is continually further developed to adapt and extend its scope of functions to meet customer requirements New versions of the operating...
Page 28: ...r using the cleanser Cleansers must not be applied directly to the casing the casing must not be immersed in the cleanser Cleaning by the manufacturer After prior consultation of the technical support...
Page 29: ...erties Casing material Aluminium anodised Casing dimensions 80 mm x 45 mm x 20 mm Weight 175 g Degree of protection IP 20 Protection class III for the operation of separated extra low voltage Paramete...
Page 30: ...s steps of 15 s Low speed shutter Integration time up to 1 second Integration Global Shutter Image recording Program controlled or external high speed trigger jitter free recording Parameters Propert...
Page 31: ...ideo frames per second fps Pixel size 4 5 H x 4 5 V m Active sensor surface 7 2 H x 5 4 V mm High speed shutter 15 s steps of 15 s Low speed shutter Integration time up to 1 second Integration Global...
Page 32: ...ligent camera You will find more detailed technical information about the accessories on the data sheets in the product catalog under www vision control com or you can contact our Support Parameters M...
Page 33: ...roper disposal of old devices can be obtained from the manufacturer local sales partner or relevant national authority Alternatively the device can be returned to the manufacturer for proper dis posal...
Page 34: ...n shall lose its validity if a modification is made to the device that we have not authorised Manufacturer Vision Control GmbH Mittelbergstra e 16 D 98527 Suhl Germany Series description Designation I...
Page 35: ...pictor N List of Changes Vision Control GmbH 2017 35 170119_999 994 899 10 en 1 0 11 LIST OF CHANGES 12 NOTES Version Date Contents Chapter...
Page 36: ...pictor N 170119_999 994 899 10 en 1 0 Vision Control GmbH 2017 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 www vision control com...