6.3.5 Connect the digital I/O interface (Digital I/O card ADDIDATA)
NOTICE
Damage of the outputs through inductive loads
•
With induced loads the outputs have to be switched with a free-wheeling diode anti-
parallel to the load.
NOTICE
Destruction caused by potential differences
•
The ground potential (GND) of the digital inputs and outputs of the device must be
connected to the ground potential (GND) of the control voltage of the device to be
controlled.
Connecting
The components required for connection are available as accessories.
option Digital I/O card ADDI-DATA"
Connect the 37-pin D-Sub connector of the unit's I/O expansion card to the process
environment using one of the following two variants:
•
I/O cable with 2 x D-Sub sockets and terminal board
•
I/O cable with 1 x D-Sub socket and open cable end
Pin assignment
Digital Input 1
Digital Input 7
Digital Input 9
Digital Input 5
Digital Input 3
Digital Input 11
Digital Input 13
Digital Input 15
24 V external outputs
0 V external inputs
Digital Output 1
Digital Output 3
Digital Output 5
Digital Output 7
Digital Output 9
Digital Output 11
Digital Output 13
Digital Output 15
Diagnose Output
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(9)
(8)
(10)
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
(26)
(28)
(27)
(29)
(30)
(31)
(32)
(33)
(34)
(35)
(36)
(37)
Digital Input 2
Digital Input 8
Digital Input 10
Digital Input 6
Digital Input 4
Digital Input 12
Digital Input 14
Digital Input 16
24 V external outputs
0 V external outputs
Digital Output 2
Digital Output 4
Digital Output 6
Digital Output 8
Digital Output 10
Digital Output 12
Digital Output 14
Digital Output 16
30
999.995.428.10-en-2.1
© Vision & Control GmbH 2022