![Vision & Control 4-21-185 Instructions For Use Manual Download Page 21](http://html.mh-extra.com/html/vision-and-control/4-21-185/4-21-185_instructions-for-use-manual_1031466021.webp)
vicosys
®
6300
Technical Data
5.5.2.2 Digital output channels
OUT-X
VDD
OUTx
GND-
OUT
GND-IO
+VDD
VDD
DIAG
(Status)
output driver
Is
ol
at
io
n
Image 13: Schematic layout of digital output channels 1 to 16
Characteristics
•
Galvanic decoupled
•
Overload protection (short circuit / overtemperature)
•
Output current limit via polyswitch fuse
•
Supply voltage monitoring
•
Output channels as high-side driver (high-active)
•
The output channels are supplied by the operating v VDD
•
ESD protection and output signal filter
•
The output channels have a common GND connection (GND-OUT)
Parameter
Parameter
Min
Nom
Max
Number of outputs
16
Operating v VDD (DC)
11 V
(1)
24 V
36 V
Output current per output
500 mA
Output current for 8 outputs
1.5 A
Short circuit current / output
(2)
1,5 A
Turn-on time
(3)
50 µs
Turn-on time
(3)
75 µs
Galvanic decoupling
present
(1)
Supply voltage < 7 V leads to an switch-off of all output channels
(2)
at pulse current, at 24 V and R
last
< 0.1 Ω
(3)
at I
out
= 0.5 A and ohmic load
© Vision & Control GmbH 2022
999.995.428.10-en-2.1
21