46
Viscount
Vivace 90
-
90 Deluxe
Owner’s Manual
1. General combinations:
this section contains the instrument’s general adjustable combinations.
When a combination is recalled, the light of the relative stop illuminates to confirm its activation.
The [NEXT] pistons can also be used to select combinations one by one in an upward direction and
[PREV.] for the same function in a downward direction (combination sequencers).
2. Division combinations:
this organ has six adjustable division combinations for Man.III (2A), Man.II
(2B), Man. I (2C) and the pedal board (2C). When a combination is recalled, the light of the relative
piston illuminates to confirm its activation.
In dedicated combinations, the user is only able to set
the configuration of the section associated to
the selected combination
.
There is also a piston marked [HR] (Handle Registers) beside the general and dedicated combinations;
also known as 0, when it is on it automatically memorises the register status. This piston’s main
function is to restore, during use of the combinations, the “hand-made” stop setup created when the
[HR] button was on. Remember that an HR setup is not modified if the stops are switched on and off
by hand when a combination on the same section is selected (i.e. with the HR off).
N.B.
The contents of the HR are not retained when the organ is switched off.
2.2 THE MANUAL SPLITTER CONTROLS
The pistons used to recall the adjustable combinations, Tutti, couplers and other accessory functions are
placed in the areas between the manuals.
HR
1
2
3
4
5
6
HR
1
2
3
4
5
6
HR
1
2
3
4
5
6
HR
1
2
3
4
5
6
HR
1
2
3
4
5
6
P
P
P
S
III
III
PREV
NEXT
I
viscount
MIDI
III
MIDI
II
MIDI
I
MIDI
P
ENC
VOL.
MENU
A.P
T
C
1
2A
2B
2C
2D
3
4A
4B
4C
5
6
7
8
9
10
11
12
13
14
Each combination (including HR and Tutti), whether general or sectional, is able to store:
-
the status (on/off) of the stops
-
the status of the couplers (enabling saving, see point 7.8)
-
the status of the tremulants (even with different modulation depths and speeds, if the specific
SET-UP menu function described in par. 7.8 is activated)
-
the style (Organ Style)
-
the MIDI controls (point 9) and the Program Changes set using the SEND PROGRAM
CHANGE function (par. 8.2)