3. Specifications
Lock Control Jumper:
To select the lock type: see 5.2.1 , 5.2.2
Door station Code DIP:
Total 4 door stations can be supported, see 6.1
Main Connect Port:
To connect the bus line and the electronic locks.
B
US: Connect to the bus line, no polarity.
PL: External lock power input, connect to the power positive (power +).
S1+, S2+: Lock power(+) output, to connect 2 locks.
S-: Lock power(-) output, connect to the power(-) input of locks (only when using the camera to
power the locks, if using the external power supply for the locks, the S- will not be connected).
Lock Power supply:
12Vdc, 300mA(Internal Power)
Power Consumption:
1W in standby, 12W in working
NO, COM dry contact:
Max. 48V dc 1.5A
Unlocking time:
1 to 9 seconds, set by Monitor
Working temperature:
-10ºC ~ 45ºC