6.3 Notices

 

 

 

 

 

 

Name

 

 

 

Description

 

 

 

Usage

 

 

 

IT-PSU24-
4A

 

Power supply,85~260Vac input,24Vdc/3A

 

output,10 DIN modules

 

Connect  with  multi  door stations  
or multi monitors up to 2 or above)

 

 

 

IT-PSU24-
1A

 

Power supply,85~260Vac input,24Vdc/1A

 

output, for basic kit only,4 DIN modules

 

Connect with one door station and 
one monitor(IT-IN35-X  can  be con-
nected two)

 

1. Parts and functions

 

2. Terminal Descriptions 

Note: IT-OUT201/2 has 2 buttons

 

www.viscoo.eu

 

Summary of Contents for IT-OUT 201-1

Page 1: ...be changed without notice to user Right to interpret and copyright of this manual are preserved Dutch office English 31 0 87 873 28 97 GMT 1 E mail support credexalarmsystems eu Webpage http www credex nl IT OUT 201 1 201 2 User Manual ...

Page 2: ...ons 6 6 Setup 12 7 Cable Requirements 15 Please read this manual carefully before using the product and keep it well www viscoo eu www viscoo eu 7 Cable Requirements The maximum distance of the wiring is limited in the 2 wired system Using different cables may also affect the maximum distance which the system can reach ...

Page 3: ...nnect with multi door stations or multi monitors up to 2 or above IT PSU24 1A Power supply 85 260Vac input 24Vdc 1A output for basic kit only 4 DIN modules Connect with one door station and one monitor IT IN35 X can be con nected two 1 Parts and functions 2 Terminal Descriptions Note IT OUT201 2 has 2 buttons www viscoo eu ...

Page 4: ...sitive power S1 S2 Lock power output to connect 2 locks S Lock power output connect to the power input of locks only when using the camera to power the locks if using the external power supply for the locks the S will not be connected Lock Power supply 12Vdc 300mA Internal Power Power Consumption 1W in standby 12W in working NO COM dry contact Max 48V dc 1 5A Unlocking time 1 to 9 seconds set by M...

Page 5: ...e are 6 bit switches in total The DIP switches are used to configure the User Code for each Monitor Bit 6 is line terminal switch which have to be set to ON if the Monitor is in the end of the line bus otherwise set to OFF 4 2 Mounting With Rain Cover 4 3 Placing Name Label Move the plastic cover away to open the transparent name label cover insert a name paper then put the plastic cover back to t...

Page 6: ...5 SystemWiring and Connections 4 4 Adjusting Camera Angle www viscoo eu 5 1 Basic Connection www viscoo eu 5 4 2 With IT MPIN Wiring Mode ...

Page 7: ... is not timed from Exit Button EB 4 The Unlock Mode Parameter of Monitor must be set to 0 by default connect one lock connect two locks 5 2 2 Door Lock Controlled with Dry Contact Note 1 The external power supply must be used according to the lock 2 The inside relay contact is restricted to AC or DC 24V 3A 3 The jumper must be taken off before connecting 4 Setup the Unlock Mode of Monitor for diff...

Page 8: ...201 2 correctly before setting 2 the parameter will be saved in 201 1 201 2 automatically so you need only set on one monitor 3 the above settings are not fit for T views series monitors Please refer to T views series monitor user manual to how to set the unlock parameter 5 3 Multi Door stations Connection ...

Reviews: