25
- Slacken screw V.
- Remove nozzle UM (fitted to air regulator Z) and
replace it with the one indicated in table TAB1.
- Retighten nozzle UM (fitted to air regulator Z).
- Adjust air regulator Z to distance A as shown in
table TAB1.
- Retighten screw V fully.
- Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING
THE
PILOT
BURNER
AND
THERMOCOUPLE.
- Open the door.
- Remove the control panel.
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
reverse order.
19.
CLEANING THE INTERIOR
Check the condition of the inside of the appliance.
- Remove any built-up dirt.
- Check and clean the fumes exhaust system.
20.
MAIN COMPONENTS
FRYERS
- Gas valve
- Main Burner
- Pilot burner
- Thermocouple
- Igniter
- Piezoelectric ignition
- Safety thermostat