covering up the source. Scalable Oxidation ensures your air purifier will perform at the maximum efficiency specific to its
environment at the time of use. In High Mode, the purification plate generates activated oxygen to assist in breaking down
contaminates which cause odours. For faster cleanup, the unit can be set to Away Mode which has a programmable auto-
shutoff timer feature. This allows the machine to generate maximum output when the room or home is unoccupied.
SPECIFICATIONS/WARNINGS
SPECIFICATIONS
UNIT
Size
: H 305 mm x W 228 mm x D 273 mm
Weight
: 4.7 kg
Coverage
: from 23 m
2
to 279 m
2
(depending on variables such as the severity and frequency of pollution, flow of air in the
environment, humidity and temperature)
Input
: 100-240 Vac - 50/60 Hz - 2.5 A
PCO CELL
“NORMAL” Mode Output
:
<
0.02 ppm ozone (ambient room concentration)
PURIFICATION PLATE
“HIGH” Mode Output
: 25-360 mg ozone per hour
IONIZATION
6 KV DC Needle Ion generator
24 - 30 KV, 20 - 30 KH3 Ion generator pulsator
WARNINGS
Review this list before use and performing any maintenance or cleaning of your unit.
WARNING
: Never operate unit near heat source, open flame or flammable/combustible fluids.
WARNING
: Do not operate unit unless all parts (including PCO Cell, Purification Plate, Rear Filter Assembly and
Rear Cover) are properly installed.
CAUTION
: Directly viewing the lamp inside unit for an extended period (longer than 20 min.) may result in
eye damage.
CAUTION
: Never adjust setting to exceed square metres of ventilated space being treated.
CAUTION
: Do not use “AWAY” Mode in occupied spaces. Short term exposure to ozone levels exceeding 0.5
ppm can cause temporary adverse reactions.
CAUTION
: Unit should be powered OFF and Power Cord should be disconnected when Cleaning/