Zero-Bias Detectors (ZBD) 

 
Virginia Diodes offers zero biased, Schottky diode detectors for a variety of millimeter wave and 
terahertz applications. These detectors provide high responsivity and extremely fast response time. VDI 
detectors offer full waveguide band coverage and are available from WR15 (50-75 GHz) to WR0.65 
(1100-1700 GHz). Higher frequency custom detectors are available upon request.  
 

Safety and Operational Guidelines  

 
Read all instructions and information in this product manual before connecting the product to external equipment. 
Operational procedures must be followed for proper function. If you have questions, contact VDI before operating the 
product.  

 
The internal components of every detector can be damaged by Electro Static Discharge (ESD). Any operator using or 
handling the device should wear a grounded wrist strap specifically designed to guard against ESD. The work 
environment including test benches should also be properly grounded. 

 

VDI assumes the customer is familiar with microwave, millimeter wave, and VDI products in general. The user and 
customer are expected to understand all safety guidelines, health hazards, and general advisories that may exist and 
are associated with the use of this device. VDI is not responsible for any human hazards that may exist or may occur 
while using this device. 

  

Virginia Diodes, Inc. (VDI) accepts no liability for damage or injury resulting from or caused by: 

 

Improper use, disassembly or use for purposes other than those for which the product was designed; 

 

 

Use outside common safety, health or general advisories pertaining to microwave, millimeter wave, and VDI products; 

 

Repairs carried out by persons other than VDI or its assigned agents. 

 
Waveguide Inspection / Test Port Care 

 

Inspect waveguide flanges for debris prior to making connections. 

 

Making a connection with metal debris between the waveguide flanges can damage the waveguide interface and prevent 
repeatable connections. 

 

If debris is present, clean the flange with pre-dampened lint free wipes or swabs (e.g. TexWipe TX1065). If these are not 
available, lint free cloths lightly dampened with ethanol may be used (e.g. TexWipe TX604). 

 

When device is not in use, cover appropriate waveguide flanges with provided dust cap or protective waveguide tape.  

 

Waveguide screws should be torqued between 20-50 cNm, greater values can damage the interface.  

 

Use a torque of 90 cNm when making coaxial connections. Avoid sharp bends in cables.  

 

General Operating Practices and Recommendations  

 

Check with VDI before any use is attempted beyond those described in this manual, including uses that may exceed 
limitations stated here or commonly accepted standards of practice.  

 

Specifications listed in this document reflect the latest specifications. For ZBDs shipped prior to July 3, 2019, please refer 
to individualized data sheets.

 

 
 
 
 
 
 
 
 
 
 
 

ZBD General Overview, Safety and Operational Guidelines

 

Summary of Contents for QOD

Page 1: ...nd Street SE Suite 309 Charlottesville VA 22902 6172 USA Tel 434 297 3257 Fax 434 297 3258 www vadiodes com 2020 Virginia Diodes Inc All Rights Reserved Zero Bias Detector Operational Manual ZBD ZBD F QOD 2020 ...

Page 2: ...e 4 5 Configurations ZBD vs ZBD F Page 6 Product Specifications Page 7 Appendix 1 ZBD Responsivity Performance Pages 8 9 ZBD Performance WR10 and WR6 5 Page 8 ZBD Performance WR5 1 and WR2 2 Page 9 Appendix 2 Responsivity vs RF Input Power Pages 10 Responsivity vs RF Input Power Page 10 Appendix 3 IF Amplifier Pre testing before use with VDI Detector Pages 11 Amplifier Pre testing before use with ...

Page 3: ...using this device Virginia Diodes Inc VDI accepts no liability for damage or injury resulting from or caused by Improper use disassembly or use for purposes other than those for which the product was designed Use outside common safety health or general advisories pertaining to microwave millimeter wave and VDI products Repairs carried out by persons other than VDI or its assigned agents Waveguide ...

Page 4: ...ons are for typical WR 3 4 zero bias detectors Other ZBDs WR 8 0 to WR 1 0 have similar configuration and dimensions High Frequency Zero Bias Detectors WR 0 8 to WR 0 65 The WR0 8ZBD has an integrated horn antenna 25dBi RF input port and a coaxial output The WR0 65ZBD has a rectangular waveguide RF input port and a coaxial output The drawing and corresponding dimensions are for a typical WR 0 65 a...

Page 5: ...etector output port using a floating voltmeter See Page 6 for configuration details ZBD F Configuration using Bias Tee and Amplifier Appropriate voltages must be applied to the voltage pins on the provided amplifier ZBD F Configuration using External ESD Protection Circuit Monitor detector output port using a floating voltmeter See Page 6 for configuration details Black Backing Plate Unused ports ...

Page 6: ...the ZBD compared to the other amplifier Therefore there will be less signal degradation through the amplifier included in the FDA option compared to the other amplifiers Amplifier gain performance assumes correct testing conditions bias voltage input impedance output impedance specified in the above table Fast Detector Options Fast Detector Option Frequency Range Gain dB typical Bias Voltage Input...

Page 7: ...h Bias Tee and Amplifier 2 9mm f ZBD F with External ESD Protection 2 9mm f RF Input Power Linear typ 25 dBm 1dB Compression typ 20 dBm Maximum RF Input Power for ZBDs only Recommended Damage for WR15 to WR2 8 0 dBm 5 dBm Recommended Damage for all other ZBDs 3 dBm 0 dBm Maximum RF Input Power for ZBD Fs only Recommended Damage for WR0 65 only 3 dBm 0 dBm Recommended Damage for all other ZBD Fs 0 ...

Page 8: ...n the output voltage and the RF input power in the linear region Measured performance data will be shipped with each ZBD Data shown in this manual is for ZBD not ZBD F configurations only ZBD Performance WR10 and WR6 5 Appendix One 0 1000 2000 3000 4000 5000 6000 75 80 85 90 95 100 105 110 Responsivity V W Frequency GHz WR10ZBD Typical 0 1000 2000 3000 4000 5000 6000 110 120 130 140 150 160 170 Re...

Page 9: ... 1 and WR2 2 0 1000 2000 3000 4000 5000 140 150 160 170 180 190 200 210 220 Responsivity V W Frequency GHz WR5 1ZBD Typical 0 500 1000 1500 2000 2500 3000 3500 4000 330 340 350 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 Responsivity V W Frequency GHz WR2 2ZBD Typical ...

Page 10: ...general shape of the curve is consistent for all diode detectors However the scale will vary with frequency and the detector design and other operating conditions for example temperature Responsivity vs RF input power data can be supplied for all shipped ZBDs at an additional cost Figure 1 Responsivity vs RF Input Power The performance responsivity vs RF input power is shown for a specific WR10ZBD...

Page 11: ...mplifier bias is applied rapidly Before using an amplifier with a VDI detector it is recommended that bias or turn on transients at the amplifier input be tested Attach a 1kΩ resistor to the input of the amplifier Monitor the resistor voltage on an oscilloscope as the amplifier bias is applied The turn on transient voltages across the resistor should be kept less than 100mV for safe operation Appe...

Page 12: ...to continually improve our products We also depend upon feedback from colleagues and customers Ideas to simplify component operations improve performance or add capabilities are always welcome Contact VDI Virginia Diodes Inc Web http www vadiodes com Email Technical vadiodes com Telephone 434 297 3257 Addendum Product Updates and Company Contacts ...

Reviews: