Viqua WS series Owner'S Manual Download Page 9

Operation

9

2.

To initiate a manual regeneration immediately, press and hold the 

REGEN

 button for three seconds. The system will 

begin to regenerate immediately. This command cannot be cancelled.

Once a manual regeneration is initiated, the unit will go into the “FILL” position, followed by the steps listed in 

Section 3.3

During this initial sequence the water softener will deliver treated water.

3.2.4 Power Loss and Battery Replacement

The AC transformer comes with a 15 foot power cord and is designed for use with the control valve; the transformer should 

only be used in a dry location.

In the event of a power outage, the control valve will remember all settings and time of day. If an extended power outage 

occurs, the control valve will keep time of day until the battery is depleted. When the battery becomes depleted, the only 

item that needs to be reset is the time of day and will be indicated by the time of day flashing. All other settings are 

permanently stored in the nonvolatile memory.

If a power loss occurs and the time of day flashes, this indicates that the battery is depleted. The time of day should be 

reset and the non rechargeable battery should be replaced. The battery is a 3 Volt lithium coin cell type 2032 and is readily 

available at most stores. To access battery location, remove front cover, refer to 

Section 5.1

.

3.2.5 Error Message

If the word “ERROR” and a number are alternately flashing on the display record the number and contact your dealer for 

help. This indicates that the control valve was not able to function properly.

3.2.6 Brine Tank Maintenance and Salt

Refill the brine tank as necessary, making sure at least 1/3 of the brine tank is full at all times. Without proper salt levels, the 

water softener may not operate properly.

The manufacturer recommends the use of solar salt for best results. The brine tank is manufactured for the use of solar, 

pellets, rock salt or block salt. If pellet or rock salt is used, a cleaning of the brine tank every six months is recommended.

3.3 Start-up Instructions

After installation is complete, rotate bypass handles to bypass mode, refer to 

Figure 2

.

Turn on water and check for leaks.

Fully open a cold water faucet - preferably a laundry sink or bathtub with no aerator.

Allow water to run until clear to rid pipes of debris which may have occurred during installation.

Note: 

“REGEN TODAY” and “TIME OF DAY” will flash alternately if a regeneration is expected tonight.

Note: 

When replacing the battery, align positives and push down to fully seat.

1

2

Summary of Contents for WS series

Page 1: ...W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Model WS Series Owner s Manual...

Page 2: ...nstalled and operated properly Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions rega...

Page 3: ...rm control valve repairs or maintenance The 1 full flow bypass valve incorporates four positions including a diagnostic position that allows a service technician to have pressure to test a system whil...

Page 4: ...ration could cause a siphoning of brine into the building If water is available on the outlet side of the softener or filter it is an indication of water bypassing the system Refer to Figure 4 i e a p...

Page 5: ...and O ring Avoid getting solder flux primer and solvent cement on any part of the O rings split rings bypass valve or control valve If the building s electrical system is grounded to the plumbing inst...

Page 6: ...l attention to codes for air gaps and anti siphon devices Note Drain line nut will not be supplied for units having a backwash rate greater than 7 gpm 7 Brine Tank Connection Install the 3 8 O D polye...

Page 7: ...display Insert the sleeve removal tool at the bottom of the sleeve 1 Press NEXT and simultaneously for 3 seconds 2 Set the amount of hardness in grains per gallon default 20 using the or buttons The...

Page 8: ...time remaining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed 3 2 3 Manual Regen...

Page 9: ...y should be replaced The battery is a 3 Volt lithium coin cell type 2032 and is readily available at most stores To access battery location remove front cover refer to Section 5 1 3 2 5 Error Message...

Page 10: ...led in Step 1 press REGEN again and the display will read SOFTENING 240 During a full regeneration this will be a 4 hour period for salt to dissolve Press REGEN again to put the valve into BACKWASH Un...

Page 11: ...line securely with rigid piping 1 Included with your backwashing filter are two check valves 3 8 John Guest push in type with a screen 1 FPT stainless steel check valve 2 The 3 8 JG valve has a small...

Page 12: ...liver soft water in this position 3 Softening Position Water in the brine tanks slowly dissolves salt in preparation for Brine Rinse Position During this cycle unit will delivery soft water Factory se...

Page 13: ...main or regenerant piston Replace main or regenerant piston Valve does not regenerate automatically when REGEN button is pressed Transformer unplugged Connect transformer and PC board power No power a...

Page 14: ...t Number Quantity 1 Front cover grey WS CV317CC 01 1 2 Motor CV3107 1 1 3 Drive bracket and spring clip CV3106 1 1 4 PC board CC CV3108CC 1 5 Drive gear 12 x 36 CV3110 3 6 Drive gear cover CV3109 1 7...

Page 15: ...2 Drive cap assembly CV3004 1 3 O ring 228 CV3153 1 4 1 piston assembly down flow CV3011 1 1 piston assembly up flow CV3011 01 1 1 25 piston assembly down flow CV3407 1 5 Regenerant piston CV3174 1 6...

Page 16: ...1 quick connect CV3151 2 2 Split ring CV3150 2 3 O ring 215 CV3105 2 4 Bypass rotor 1 CV3145 2 5 Bypass cap CV3146 2 6 Bypass handle CV3147 2 7 Bypass rotor seal retainer CV3148 2 8 O ring 135 CV3152...

Page 17: ...01 1 7 0 7 DLFC for 3 4 elbow CV3162 007 1 1 0 DLFC for 3 4 elbow CV3162 010 1 1 3 DLFC for 3 4 elbow CV3162 013 1 7 DLFC for 3 4 elbow CV3162 017 2 2 DLFC for 3 4 elbow CV3162 022 2 7 DLFC for 3 4 el...

Page 18: ...A 5 6 Injector Assembly Item Description Part Number Quantity 1 Refill port plug assembly CV3195 01 1 2 Elbow locking clip CH4615 1 3 Tube insert 3 8 CJCP P 6 1 4 Nut 3 8 CJCPG 6PBLK 1 5 Elbow cap 3 8...

Page 19: ...r assembly Red CV3010 1D Injector assembly White CV3010 1E Injector assembly Blue CV3010 1F Injector assembly Yellow CV3010 1G Injector assembly Green CV3010 1H Injector assembly Orange CV3010 1I Inje...

Page 20: ...w set CH1018 1 3 474 air check assembly 1 2 x 48 CH4500 48 1 4 474 float assembly 32 with two grommets CH4640 32 1 5 474 safety brine valve with 0 5 gpm flow control CH4600 50 1 6 Cap 4 brine well CH7...

Page 21: ...Quantity 1 474 0 5 gpm flow control CH4655 1 2 O ring 019 CH3163 1 3 3 8 elbow cap CH4613 1 1 2 elbow cap CH4612 4 Elbow locking clip CH4615 1 5 3 8 compression nut CJCPG 5PBLK 1 1 2 compression nut C...

Page 22: ...Injector and Bypass Caps 4 Loosening Quick Connect Nuts Item Description Part Number Quantity 1 Salt and tank cover must be ordered together CG2197 01 1 2 Windsor cabinet white with black lids CG2724...

Page 23: ...tem Description Part Number Quantity 1 Nut 1 quick connect CV3151 1 1 Nut 1 quick connect CV3151 1 2 Split ring CV3150 1 2 Split ring CV3150 1 3 O ring 215 CV3105 1 3 O ring 215 CV3105 1 4 Fitting CV3...

Page 24: ...100 F 0 5 37 7 C 33 100 F 0 5 37 7 C 33 100 F 0 5 37 7 C 33 100 F 0 5 37 7 C 33 100 F 0 5 37 7 C 33 100 F Electrical Requirements 110 V 50 60 Hz 110 V 50 60 Hz 110 V 50 60 Hz 110 V 50 60 Hz 110 V 50...

Page 25: ...0 5 37 7 C 33 100 F Electrical Requirements 110 V 50 60 Hz 110 V 50 60 Hz Pipe Size 3 4 brass 3 4 brass Total Dimension Media Tank width x height 25 4 cm x 11 71 cm 10 x 44 25 4 cm x 137 1 cm 10 x 54...

Page 26: ...0 gpm 15 1 lpm 5 0 gpm 18 9 lpm 8 0 gpm 30 3 lpm Peak Flow 5 0 gpm 18 9 lpm 6 0 gpm 22 7 lpm 8 0 gpm 30 3 lpm 5 0 gpm 18 9 lpm 6 0 gpm 22 7 lpm 9 0 gpm 34 1 lpm Backwash Flow 5 0 gpm 18 9 lpm 5 0 gpm...

Page 27: ...st minutes with U and V buttons 5 Press NEXT to complete and return to normal operation Bypass To shut off water to the system position arrow handles as shown in the bypass operation diagram below If...

Page 28: ...y does not cover change in water test mis application of media use of mineral cleaners in brine tank including salt additives lack of maintenance or any other acts of God VIQUA will not be responsible...

Page 29: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...