Operation
7
Section 3
Operation
3.1 Programming Procedures
3.1.1 Set Time of Day
Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an
extended power outage occurs, the time of day will flash on and off indicating that the time should be reset.
Procedure:
3.1.2 Programming
Note:
The manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated after
the hardness is entered.
Procedure:
1
•
Press
SET CLOCK
.
2
•
For Current Time (hour), set the
hour of the day using
+
or
–
buttons. “
AM
/
PM
” toggles after 12.
Press
NEXT
.
3
•
For Current Time (minutes), set the minutes using
+
or
–
buttons. If it is desired
to back up to the previous step press
REGEN
button once.
•
Pressing
NEXT
will exit
SET CLOCK
and return to the general operating
display.Insert the sleeve removal tool at the bottom of the sleeve.
1
•
Press
NEXT
and
+
simultaneously
for 3 seconds.
2
•
Set the amount of hardness in grains per gallon (default
20) using the
+
or
–
buttons.
•
The allowable range is from 1 to 150 in 1 grain
increments.
Note:
Increase the grains per gallon if soluble iron is
present (1 ppm = 4 gpg). This display will show “–nA–”
(not available) if “FILTER” is selected or if “AUTO” is not
factory set. Press
NEXT
or press
REGEN
to exit.
3
•
Set Day Override using
+
or
–
buttons (12 is recommended):
•
Set number of days between regeneration (1 to 28) or
•
Set to “
OFF
”
•
Press
NEXT
or press
REGEN
to return to the previous step.
Note:
The manufacturer has factory set 12 days as the
default. This is the maximum number of days between
regenerations. If this is set to “OFF”, regeneration initiation
is based solely on gallons used. If any number is set
(allowable range from 1 to 28), a regeneration initiation will
be called for on that day even if a sufficient number of
gallons were not used to call for a regeneration.