Maintenance

9

4.2 Cleaning and Replacing Quartz Sleeve

Note: 

Minerals in the water slowly form a coating on the lamp sleeve. This coating must be removed because it reduces the 

amount of UV light reaching the water, thereby reducing disinfection performance. If the sleeve can not be cleaned, it must 
be replaced.

Prerequisites:

Shut off water supply and drain all lines.

Place a small pail under the unit to catch any spills.

Remove the UV lamp. Refer to 

Section 4.1

.

Procedure:

Note: 

If the system is put on a temporary by-pass or if it becomes contaminated after the disinfection system, it is necessary 

to shock the system with household bleach for a full 20 minutes before resuming the use of the water.

1

•   

Drain the UV chamber by 
using the drain port.

2

1

2

3

•   

Remove the bottom retaining 
nut, floating spring, and O-
ring.

3

1
2

•   

Remove the top retaining nut 
and O-ring.

4

•   

Remove the quartz sleeve.

5

Mild 
Acid

•   

Clean the quartz sleeve with 
a cloth soaked in CLR, 
vinegar or some other mild 
acid and then rinse with 
water.

6

•   

Reinstall the quartz sleeve in 
the UV chamber allowing the 
sleeve to protrude an equal 
distance at both ends of the 
UV chamber.

•   

Slide supplied and lubricated 
O-rings onto each end of the 
quartz sleeve.

7

1

2

1

2

3

•   

Reinstall the top and bottom 
retaining nuts, floating spring, 
and O-rings respectively.

•   

When service is complete, 
assemble the prerequisites in 
the reverse order of 
disassembly.

8

1

2

click

•   

Push the lamp connector 
against lamp connector base 
together until an audible click 
is heard.

•   

Plug in controller and verify 
the POWER-ON LED is 
illuminated and controller 
power-up sequence 
operates.

•   

Re-pressurize the system to 
check for leaks.

Summary of Contents for S2Q-PV

Page 1: ...ario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models S2Q PV S5Q PV S5Q PV ASPL Owner s Manual Powered by 520026_RevM ...

Page 2: ...hy should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equipment An increasing number of calls to VIQUA Technical Support are connected with non genuine lamps being used unknowingly as replacements Damage arising from the use of non genuine lamps poses a safe...

Page 3: ...GFCI This symbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipment Unless a situation is encountered that is explicitly addressed by the provided maintenance and trou...

Page 4: ...ry If the lamp breaks then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guidelines for the removal and disposal of mercury waste NOTICE The UV lamp inside the disinfection system is rated at an effective life of approximately 9000 hours To ensur...

Page 5: ...tems 2 Spring SP008 Used on all systems 3 Chamber Used on all systems 4 Connector base 270276 Used on all systems 5 Open Ended 214 fused quartz sleeves with fire polished ends QS 330 S2Q PV QS 463 S5Q PV ASPL S5Q PV 6 O ring 410867 R Used on all systems 7 Retaining nut RN 001 Used on all systems 8 Hard glass coated Sterilume EX UV lamps for long consistent life 9000 hours S330RL S2Q PV S463RL S5Q ...

Page 6: ...l fire hazard Drip loops in all cordage connected to controller is highly recommended The complete water system including any pressure or hot water tanks must be sterilized before start up by flushing with chlorine household bleach to destroy any residual contamination The disinfection system is intended for indoor use only Do not install disinfection system where it may be exposed to the weather ...

Page 7: ...n power must be removed for 30 seconds to allow ballast to reset 2 As the system requires time to reach its full operating capacity please allow the disinfection system to operate 3 5 minutes prior to using the water from the unit In addition to clear any air or debris from the system allow water to run through the disinfection system for 2 3 minutes when using an RO application run the water for ...

Page 8: ... allow the unit to cool for 10 minutes 3 1 2 Remove the lamp connector by squeezing the plastic locking tabs on the side of the connector 4 Hg UV Remove the UV lamp in upward direction from the chamber and lamp connector base Hold the UV lamp at the ceramic ends 5 Hg UV 1 2 Insert the new lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber 6 Attach the conn...

Page 9: ...using the drain port 2 1 2 3 Remove the bottom retaining nut floating spring and O ring 3 1 2 Remove the top retaining nut and O ring 4 Remove the quartz sleeve 5 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water 6 Reinstall the quartz sleeve in the UV chamber allowing the sleeve to protrude an equal distance at both ends of the ...

Page 10: ...rews and plug the connector back onto the ballast Alarm side Section 5 Specifications C A U T I O N Ensure Alarm connector is connected to the Alarm side of the Ballast Model S2Q PV S5Q PV S5Q PV ASPL Flow Rate 1 US Public Health 16mJ cm2 5 gpm 19 lpm 0 9 m3 hr 11 gpm 42 lpm 2 5 m3 hr 11 gpm 42 lpm 2 5 m3 hr Standard 30 mJ cm2 3 gpm 11 lpm 0 7 m3 hr 6 gpm 23 lpm 1 4 m3 hr 6 gpm 23 lpm 1 4 m3 hr NS...

Page 11: ...r Electrical and Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty Please return the defective part to your dealer who will process your claim One Year L...

Page 12: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com ...

Reviews: